Stand-alone installation tests
II
............................................................................................................................................................................................................................................................
Tools, test equipment, and accessories
This section lists the tools, test equipment and accessories needed to perform all the
procedures in this installation manual.
Listed below are the required tools, test equipment and accessories.
Quantity
1
1
1
1
1
1
2 or 3
2
1
1
............................................................................................................................................................................................................................................................
II - 2
Description
Screwdriver(s)
ESD Wrist Strap
Multimeter
(Optional)
DS1 Error Rate Test
Set
DS3 Error Rate Test
Set
SONET Optical Test
Set
Optical Power Meter
LC-type Optical
Fiber Jumper
(108918269)
15 dB LC-type LBO
(108279480)
Personal Computer
(PC)
CIT Interface Cable
Comments
A screwdriver(s) with the appropriate head(s) is (are)
required for securing the mounting screws, repositioning
the mounting brackets, installing the interfacing cables,
and for setting the circuit breakers to the OFF position.
A wrist strap must be worn when handling circuit packs.
Use the electrostatic discharge (ESD) jack provided on the
shelf.
The voltmeter must be capable of measuring DC voltage
in the 40 to 60 volt range. The use of the voltmeter is
optional since the shelf will alarm or shut down if the
proper voltage is not supplied.
A DS1 error rate test set is required for testing of DS1
cabling. A T-BERD 211 or equivalent is recommended.
A DS3 error rate test set is required for testing of DS3
cabling. A T-BERD 305 or equivalent is recommended.
An OC-3, OC-12, or OC-48 test set is required for testing
of optical circuit packs. An Agilent OmniBER 718 or
equivalent is recommended.
An optical power meter capable of measuring optical
levels from +5.0 dBm to -30.0 dBm. The meter should
also have adapters for LC type connectors and any other
connectors used in the office.
Two optical fiber jumpers with LC type connectors are
required to optically loop the Alcatel-Lucent 1665 DMX
shelf for test purposes.
Two 15-dB LBOs are required when optically looping the
Alcatel-Lucent 1665 DMX shelf for test purposes.
See
Chapter 5, "Software download and circuit pack
installation",
"PC minimum requirements" (p.
8-ft. long RJ45 to 9-pin D-sub serial cable (Comcode
848748869).