Installation tests
............................................................................................................................................................................................................................................................
This procedure requires the use of a DS3 test set.
Note:
port" basis for DS3 or EC1. The default setting for all ports is DS3. Tests in the section
will verify proper cabling by using a DS3 test set with all ports provisioned as DS3.
Verify provisioning
Verify that all ports are provisioned as DS3.
........................................................................................................................................................................................................................
1
Select View > Equipment...
........................................................................................................................................................................................................................
2
Click on the "+" sign next to the CP fn with the DS3/EC1 circuit pack.
........................................................................................................................................................................................................................
3
Verify that all ports are labeled as DS3.
........................................................................................................................................................................................................................
4
To change provisioning from EC1 to DS3, select Configuration > Equipment... Select
the DS3/EC1 circuit pack and port, then choose DS3 and click Apply.
........................................................................................................................................................................................................................
5
Repeat
circuit pack(s).
........................................................................................................................................................................................................................
6
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
DS3 terminating equipment loopback testing (optical main OLIUs)
When the Alcatel-Lucent 1665 DMX is equipped with optical main OLIUs, they are
looped on themselves and the following tests verify correct operation.
When the Alcatel-Lucent 1665 DMX is equipped with LNW80 switch packs or LNW59
mains without optics, go to
and LNW59 without optics) (p.
Facility Loopback testing allows the installer to verify the electrical cabling to the Alcatel-
Lucent 1665 DMX NE. Follow the procedure below to perform a facility loopback test at
the Alcatel-Lucent 1665 DMX shelf. When the Alcatel-Lucent 1665 DMX is cabled to
............................................................................................................................................................................................................................................................
6 - 1 8
The LNW16 and LNW19/LNW19B circuit packs are provisioned on a "per
Step 1
through
Step 4
S
F
T E P S
DS3 terminating equipment loopback testing (LNW80 switch
for each Function Group equipped with DS3/EC1/TMUX
Table I-3, Installation acceptance
6-20).
DS3/EC1 and TMUX testing procedure
checklist.
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010