Installation tests
............................................................................................................................................................................................................................................................
Result:
and NE LEDs should be lit on the SYSCTL circuit pack.
........................................................................................................................................................................................................................
20
From the system view click Alarm List to verify that the circuit pack alarm is associated
with the optical port being tested.
........................................................................................................................................................................................................................
21
Select Configuration > Update System... > Update All.
Requirement: The flashing FAULT LED should extinguish on the OC-3 OLIU. There
should be no alarm indications on the Alcatel-Lucent 1665 DMX shelf.
........................................................................................................................................................................................................................
22
Remove the 15-dB LBO from the OC-3 OLIU (port 4).
........................................................................................................................................................................................................................
23
Replace all protective dust covers on the OC-3 OLIU connectors (OLIU and LGX), that
were removed to perform this procedure.
........................................................................................................................................................................................................................
24
Repeat this entire procedure for each OC-3 OLIU in the Alcatel-Lucent 1665 DMX shelf.
........................................................................................................................................................................................................................
25
Check off the appropriate box in
E
O
N D
........................................................................................................................................................

OC-12 (low-speed) testing

OC-12 testing procedure
Perform the following steps for all Alcatel-Lucent 1665 DMX shelf Function unit or
Growth slots containing OC-12 OLIU circuit packs.
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
The FAULT LED should begin flashing on the OC-3 OLIU and only the MN
S
F
T E P S
NOTICE
Laser safety
When connecting fiber loops between the IN and OUT ports on optical circuit
packs, always connect to the IN port first and then the OUT port. This will
prevent any optical radiation from being present at the fiber end.
Table I-3, Installation acceptance
OC-12 (low-speed) testing
checklist.
6 - 3 9