Table Ds3 Cable Assemblies With Bnc With 12-Ds3 (Lnw16/Lnw18) - Alcatel-Lucent 1665 Installation Manual

Data multiplexer (dmx)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Equipment and cable installation
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
8
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
Table 1-12 Table DS3 Cable assemblies with BNC with 12-DS3 (LNW16/LNW18)
Description
12 individual 735A
coaxial cables with 12
ITT Canon 75-ohm BNC
plugs shipped loose.
DS3#1-12 Cables with no
BNC, LNW16, LNW18
only
849040779 uses 735A
cable, and 450 ft is the
maximum amount of
735A allowed between
two Alcatel-Lucent 1665
DMXs
849041710 and lengths
>450 ft use ~10ft 735A
spliced to 734D cable and
900 ft is the maximum
amount of 734D allowed
between two Alcatel-
Lucent 1665 DMXs. This
splice is factory made.
Stagger the splices in the
cable rack to save space
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 2 March 2008
S
F
T E P S
Cable
assembly #
848955407
848955415
848955423
848955431
848548277
848980504
848548285
848548293
848548301
848548319
848815742
848815734
848815759
12-DS3/EC1 and TMUX (LNW16 LNW18) cable installation
Appendix E, "Installation
Cable length
(feet)
10
20
30
40
50
60
100
150
250
450 (NE to
NE)
450 (NE to
NE)
750 (NE to
NE)
900 (NE to
NE)
checklist".
Alcatel-Lucent 1665 DMX
backplane connections
Output
Input
Function Group A
J1 DS3 1-12
J2 DS3 1-12
Function Group B
J3 DS3 1-12
J4 DS3 1-12
Function Group C
J6 DS3 1-12
J5 DS3 1-12
Function Group D
J8 DS3 1-12
J7 DS3 1-12