Equipment and cable installation for 1665 Data Multiplexer
(1665 DMX)

12TMUX (LNW18) cable installation

............................................................................................................................................................................................................................................................
Description
This section describes how to connect the TMUX cables to the 1665 DMX High-Capacity
shelf and route the cables out of the bay and to the TMUX terminating equipment.
Perform this procedure if TMUX cables are required for an LNW18 in a function group.
It should be noted that the cables used for 12TMUX support are DS3 cables (12 port). The
new high capacity DS3 cables will also support 12TMUX, but only in a 12 port capacity.
Important!
becomes an extension of the 1665 DMX High-Capacity shelf backplane connections.
Therefore, the IN on the 1665 DMX High-Capacity shelf backplane connects to the IN
of the DSX and the OUT of the 1665 DMX High-Capacity shelf backplane connects to
the OUT of the DSX.
TMUX cable options are listed in
(p.
1-44).
TMUX transmission connections are in
(p.
1-57). Total of four function groups fully cabled will have 48 DS3 drop capacity.
Procedure
Proceed as follows:
........................................................................................................................................................................................................................
Refer to the engineering job specification. Obtain the TMUX (DS3) cables per
1
"DS3/EC1 or TMUX cable assemblies" (p. 1-44)
cable will be used. Label the cables, indicating bay, shelf, function group (A, B, C or D)
and direction (IN or OUT of the bay) at each end.
........................................................................................................................................................................................................................
Connect the function group cables at the 1665 DMX High-Capacity shelf end, carefully
2
matching the correct connector with the appropriate backplane connectors as shown in
Figure 1-16, "12TMUX cable installation" (p.
Important!
maximum of 6.5 in-lb. Do not overtighten.
............................................................................................................................................................................................................................................................
1 - 5 4
When cabling the 1665 DMX High-Capacity shelf to a DSX, the DSX
Table 1-7, "DS3/EC1 or TMUX cable assemblies"
DS3/EC1 and TMUX cable retaining screws must be tightened to a
12TMUX (LNW18) cable installation
Table 1-9, "12TMUX transmission connections"
and note the function group where each
1-55).
Table 1-7,
365-372-304R7.1
Issue 1, November 2007