ABB IRB 6660 Product Manual page 362

Hide thumbs Also See for IRB 6660:
Table of Contents

Advertisement

5 Calibration
5.4.4 Axis Calibration - Running the calibration procedure
Continued
After calibration
1
2
3
362
Action
Check the o-ring on the fixed calibration pin.
Replace if damaged or missing.
Reinstall the protective cover on the fixed calibra-
tion pin on each axis, directly after the axis has
been calibrated.
Replace the cover with new spare part, if missing
or damaged.
Reinstall the protective plug and sealing in the
bushing on each axis, directly after the axis has
been calibrated. Ensure that the sealing is not
damaged.
Replace the plug and the sealing with new spare
part, if missing or damaged.
© Copyright 2007-2018 ABB. All rights reserved.
Note
xx1600002102
Protection cover and plug set:
3HAC056806-001.
xx1500000952
Protection cover and plug set:
3HAC056806-001.
Product manual - IRB 6660
3HAC028197-001 Revision: S

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 6660 - 100/3.3Irb 6660 - 130/3.1Irb 6660 - 205/1.9

Table of Contents