Advertisement

4 Repair
4.3.3 Replacement of cable harness, upper end
Continued
2
3
4
5
Continues on next page
198
Action
In order to facilitate refitting of the cable
harness, run the robot to the specified pos-
itions:
Axis 1: 0°
Axis 2: 0°
Axis 3: 0°
Axis 4: 0°
Axis 5: +90°
Axis 6: no significance
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the ro-
bot
air pressure supply to the robot
Before entering the robot working area.
Before starting the removal of the axes-4-6
cable harness, first remove the cable har-
ness of axes 1-3.
Remove the cover, wrist unit in order to
reach the cable harness at axes 5 and 6.
Note
Foundry Plus
Make sure not to lose the washers placed
in the holes of the foundry gasket.
xx1400002580
© Copyright 2007-2018 ABB. All rights reserved.
Note
Note
Axis 5 must be oriented in the correct po-
sition (+90°) to allow the cover of motor
axis 6 to open.
Detailed in the section
Replacement of
cable harness, lower end (axes 1-3) on
page
181.
xx0700000140
A : Cover, wrist unit