4 Repair
4.6.4 Replacement of motor, axis 5
Continued
Equipment, etc.
Removal tool, motor M10x
Measuring tool
Guide pins M8 x 100
Guide pins M8 x 150
Power supply
Standard toolkit
Other tools and procedures
may be required. See refer-
ences to these procedures
in the step-by-step instruc-
tions below.
Circuit diagram
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
1
Continues on next page
298
Art. no.
3HAC14972-1
6896134-GN
3HAC15520-1
3HAC15520-2
-
-
-
Action
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
© Copyright 2007-2018 ABB. All rights reserved.
Note
Always use the removal tools in pairs!
For guiding the motor.
For guiding the motor.
24 VDC, 1.5 A
For releasing the brakes.
Content is defined in section
ard tools on page
381.
These procedures include references
to the tools required.
See chapter
Circuit diagram on
page
389.
Note
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
Reference calibration
routine on page
353.
Read more about reference calibration for
Pendulum Calibration in Operating manu-
al - Calibration Pendulum.