8.7 Main Power Hookup - Challenge CMT-130TC Service Manual

Book trimmer
Table of Contents

Advertisement

8.7 Main Power Hookup

This section describes how to hookup main
power to the CMT-130. These procedures
should be performed by a licensed electrician
that is familiar with the local electrical codes in
your area.
An adequate power supply must be provided to
the machine. See GP 6.16 Specifications for
power requirements. Power to the trimmer
should be on its own circuit with a lockable, dis-
connect switch. Too many machines on the
same circuit will reduce power to each machine.
Insufficient voltage may cause overheating, loss
of cutting/clamping force, and/or failure to oper-
ate.
The following table lists recommended wire
sizes for different voltage options. If a wire is
run over 75 feet (23 meters), the next size wire
should be used. Be sure to always follow your
local electrical codes.
Recommended Wire Sizes
for Main Power Hookup
Circuit
Minimum
V
Size
Wire Size
A
# AWG
380/415
20
12
230
30
10
208
30
10
Power Hookup Procedure
WARNING
Shock Hazard! Always disconnect power at
main disconnect switch before working on
the trimmer. Lock it out to prevent acci-
dental power up. See Power Lockout Proce-
dure on page ix.
CMT-130TC Book Trimmer
1. Locate the power panel door at the lower
right-hand side of the machine (Figure 8-40)
and remove the door.
Metric
Wire
2
mm
Figure 8-40. Power Panel Door
2.5
4
2. Route the incoming power cable under the
4
right-hand side of the machine and behind
the power panel enclosure.
3. Locate the cable hole in the lower left-hand
corner of the power panel (Figure 8-41).
Mount a strain relief in this hole.
4. Route the cable through the strain relief and
into the power panel area.
5. Locate the terminal block at the lower, left-
hand corner of the power panel (Figure
8-41). The ground screw is located beneath
the terminal block.
MAY 2019
8-17
6. Fasten the ground lead to the ground termi-
nal lug as shown in Figure 8-41.
Figure 8-41. Power Panel
7. Fasten the three power leads to the three
terminals L1, L2, and L3 (Figure 8-41) on
the main power terminal block.
8. Replace all panel doors.
9. Make sure compressed air is connected to
the machine and is switched on (See Sec-
tion 8.8 Main Air Hookup).
I
10. Unlock and switch on (
) the supply power
disconnect switch.
I
11. Switch on (
) the machine's power.
12. Press the green start button key on the front
console (Figure 8-42) to initiate the machine.
8. Installation