GP 6.12 Hirschmann Connectors
Hirschmann connectors are used on all three hy-
draulic solenoid valves at the manifold and on
the proportional air valve. The following proce-
dure describes how to disassemble Hirschmann
connectors to check for loose or shorted wires.
Procedure
1. Switch the main power OFF and lockout
power to the machine.
2. Using a small screwdriver, completely re-
move the mounting screw from the con-
nector.
3. Remove the Hirschmann connector from the
solenoid by pulling the connector away from
the solenoid.
4. Disconnect the strain relief nut on the end of
the connector.
5. Pry the bottom of the connector out.
6. Push the cable into the connector to reveal
the contacts.
7. Inspect the contacts for loose or shorted
wires. Re-connect wires as necessary.
8. Assemble and reinstall the connector.
CMT-130TC Book Trimmer
Figure 6-15. Hirschmann Connector
MAY 2019
6-13
6. General Procedures/Information