Rap 2.15 Starter Circuit - Challenge CMT-130TC Service Manual

Book trimmer
Table of Contents

Advertisement

RAP 2.15 Starter Circuit

Inputs 1 and 24, Output 7
The IR relay enables the operation of several
actions within the trimmer and accessories. It
also enables the operation of the hydraulic mo-
tor relay (HMR). The HMR relay enables opera-
tion of the hydraulic system. Both relays oper-
ate simultaneously.
Output 7 should be on when input 1 and 24 are
on.
Possible Fault Indicators
The hydraulic system will not switch on.
The gripper transport will not initialize on
startup.
An Interlock Relay error message is dis-
played on the screen.
A motor starter error message is dis-
played on the screen.
Initial Actions
Check for loose wires at the HMR and IR relays.
Check for loose wires at all door interlocks, start,
and e-stop buttons. Check for loose wires at the
overload relay, OLH which is mounted to the
HMR relay.
Procedure
1. Go to RAP 2.13 Start/Remote Cut Buttons.
2. Go to RAP 2.14 E-Stop/Remote E-Stop But-
tons.
3. Go to RAP 2.16 Hydraulic Motor Relay.
4. Go to RAP 2.12 Interlock Relay.
5. Go to RAP 2.10 Door Interlocks.
CMT-130TC Book Trimmer
6. Call for technical support. The hydraulic
motor may need replacement (PL 5.23 Hy-
draulic Power Unit – 60Hz 59010 or
7. PL 5.24 Hydraulic Power Unit – 50Hz
59010-1).
Figure 2-18. HMR and IR Relays