3 MOTION DEDICATED PLC INSTRUCTION
3.2.5 Speed change instruction from the PLC CPU to the Motion CPU: D(P).CHGV
(PLC instruction: D(P).CHGV )
Internal devices
Setting
(System, User)
data
(Note-3)
Bit
Word
(n1)
(S1)
(n2)
(D1)
(Note-2)
(Note-1)
(D2)
(Note-2)
(Note-1)
[Instruction]
DP.CHGV
D.CHGV
Link direct device
File register
J \G
Bit
Word
Bit
(Note-2)
(Note-2)
(Note-1): Omission possible with both of (D1) and (D2) omission.
(Note-2): Local devices cannot be used.
(Note-3): Setting data (n1) to (D2) : Index qualification possible (except constant)
[Condition]
Command
Command
Command
Command
Usable devices
Unit access device
U \G
Word
Bit
Word
DP.CHGV
(n1)
DP.CHGV
(n1)
(S1)
(n2)
D.CHGV
(n1)
D.CHGV
(n1)
(S1)
(n2)
3 - 33
Constant
Index
register
Decimal K,
Real
Z
Hexadecimal
character
H
string
: Usable
(S1)
(n2)
(D1)
(D2)
(S1)
(n2)
(D1)
(D2)
Others
: Usable partly