3 MOTION DEDICATED PLC INSTRUCTION
[Start accept flag (System area)]
CPU shared memory address
( ) is decimal address
The complete status of start accept flag is stored in the address of start accept flag in
the CPU shared memory for target CPU.
The start accept flag for 32 axes are stored corresponding to each bit.
Bits are actually set as the following:
• Q173DSCPU/Q173DCPU(-S1) : J1 to J32
• Q172DSCPU
• Q172DCPU(-S1)
204H(516)
OFF : Start accept enable
205H(517)
ON : Start accept disable
The command generation axis start accept flag for 32 axes are stored
corresponding to each bit.
Bits are actually set as the following:
• Q173DSCPU: J1 to J32
• Q172DSCPU: J1 to J16
20EH(526)
OFF : Start accept enable
20FH(527)
ON : Start accept disable
QDS
b15
b14
204H(516) address
J16
205H(517) address
J32
b15
b14
20EH(526) address
J16
20FH(527) address
J32
3 - 10
Description
: J1 to J16
: J1 to J8
b2
b1
b0
J2 J1
J18 J17
b2
b1
b0
J2 J1
J18 J17