Mitsubishi Electric Melsec Q Series Programming Manual page 361

Motion controller (sv13/sv22)
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

5 OPERATION CONTROL PROGRAMS
(3) In (S2), write directly the spreadsheet cell or tag as a 32 one-byte character or
less character string enclosed with double quotation, or set the head of a device in
which a 32 one-byte character or less character string is stored.
Designation methods of the character string are shown below.
The spreadsheet row (A to Z) and line (0 to 399) are arranged and written.
Setting with cell
(Example) When cell is A5, "A5" is set.
The Symbolic tag name is written in the original state.
Setting with tag
(Example) When tag is Job.Pass_count, "Job.Pass_count" is set.
(4) In (S3), set the head of a device that store data to be transferred to spreadsheet
cell or tag.
Data type specified with (S3)
16-bit integer value type
32-bit integer value type
64-bit floating-point type
Also, the character string of constants or 99 one-byte character or less character
string can be specified directly.
Data type specified with (S3)
16-bit integer value type
32-bit integer value type
64-bit floating-point type
Character string
POINT
If the floating-point data is transferred to the vision system, it is handled as 32-bit
floating-point data. The number of effective digits is approx. 7 digits. Data in the
seven digits or later may not match the (S3) data.
(5) (S4) is set in increments of 10ms.
When the setting is omitted, the timeout time is 10 seconds (same as setting
1000).
Number of points
1 point
Consecutive 2 points
Consecutive 4 points
Setting example
K12345
K12345678L
K1234.5
"MITSUBISHI"
5 - 138
Setting example
D1000
D2000L
D3000F

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents