Mitsubishi Electric Melsec Q Series Programming Manual page 478

Motion controller (sv13/sv22)
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

12 ERROR CODE LISTS
Error
Details
code
code
Name
Operation (/)
16320
execution error
Remainder (%)
16321
execution error
Device set (SET)
16322
execution error
Device reset (RST)
16333
execution error
Device set (SET=)
16334
execution error
Device reset (RST=)
16335
execution error
Device output (DOUT)
16336
execution error
Device input (DIN)
16337
execution error
Bit device output
16338
(OUT=) execution
error
Direct specification 16
bit Multiple CPU area
16368
device for CPU No.1
(U3E0\G10000 to)
read error
Direct specification 32
bit Multiple CPU area
16369
device for CPU No.1
(U3E0\G10000 to)
read error
Direct specification 64
bit Multiple CPU area
16370
device for CPU No.1
(U3E0\G10000 to)
read error
Direct specification 16
bit Multiple CPU area
16371
device for CPU No.2
(U3E1\G10000 to)
read error
Direct specification 32
bit Multiple CPU area
16372
device for CPU No.2
(U3E1\G10000 to)
read error
Direct specification 64
bit Multiple CPU area
16373
device for CPU No.2
(U3E1\G10000 to)
read error
Direct specification 16
bit Multiple CPU area
16374
device for CPU No.3
(U3E2\G10000 to)
read error
Direct specification 32
bit Multiple CPU area
16375
device for CPU No.3
(U3E2\G10000 to)
read error
Error factor
Description
The divisor is 0.
• The device No. which indirectly specifies
(D) is illegal.
• (D) is a device which is write-disabled.
The device No. which indirectly specifies (D)
is illegal.
Multiple CPU area device number is outside
the range that set by the parameter.
12 - 11
Error Processing
Correct the program so that the divisor is
other than 0.
• Correct the program so that the device No.
which indirectly specifies (D) is proper.
• Correct the program to set a write-enabled
device at (D).
Correct the program so that the device No.
which indirectly specifies (D) is proper.
The block processing
on executing is
stopped and the next
block is executed.
Correct the program so that Multiple CPU
area device number is within the range set
in the parameter.
Corrective Action

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents