Mitsubishi Electric Melsec Q Series Programming Manual page 128

Motion controller (sv13/sv22)
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

3 MOTION DEDICATED PLC INSTRUCTION
[Start accept flag (System area)]
CPU shared memory address
( ) is decimal address
[Errors]
(Note-1)
Complete status
(Error code)(H)
0010
2100
2203
When the instruction is executed by specifying "Jn" as Axis No., the complete status of
start accept flag is stored in the address of the start accept flag in the CPU shared
memory for target CPU.
The start accept flag for 32 axes are stored corresponding to each bit.
Bits are actually set as the following:
• Q173DSCPU/Q173DCPU(-S1) : J1 to J32
• Q172DSCPU
• Q172DCPU(-S1)
204H(516)
OFF: Start accept enable
205H(517)
ON : Start accept disable
The abnormal completion in the case shown below, and the error code is stored in the
device specified with the complete status storage device (D2).
If the complete status storage device (D2) is omitted, an error is not detected and
operation becomes "No operation".
Instruction request to Motion CPU from PLC CPU exceeds the permissible
value.
There are the following number or more simultaneous D(P).SVST/
D(P).CHGA/D(P).CHGAS
the PLC CPU, therefore the Motion CPU cannot process them.
• Q173DSCPU/Q172DSCPU
• Q173DCPU(-S1)/Q172DCPU(-S1) : 65 or more
Axis No. set by D(P).CHGA instruction is wrong.
b15
204H(516) address
J16
205H(517) address
J32
Error factor
instruction requests to the Motion CPU from
QDS
(Note-2)
: 129 or more
(Note-1): 0000H (Normal)
(Note-2): 65 or more for operating system software version "00A".
3 - 17
Description
: J1 to J16
: J1 to J8
b14
Confirm a program,
and correct it to a
correct sequence
program.
b2
b1
b0
J2 J1
J18 J17
Corrective action