APPENDICES
(3) System setting data of the Motion CPU
System setting is shown below.
(a) Module setting
1) Motion module setting
Manual pulse generator interface module (Q173DPX : Slot 3)
Axis No.
P1
P2
I/O response time
2) PLC module setting
Module
type
Input
Output
Manual pulse generator, Synchronous encoder (INC)
Manual pulse generator, Synchronous encoder (INC)
Occupied
Points
I/O No.
16
000-00F
16
010-01F
APP - 30
Description
0.4[ms]
Base
Slot No.
Main Base
1
Main Base
2
I/O response
time
10[ms]