5 OPERATION CONTROL PROGRAMS
Off set
Name
+0
Resolution
+1
Auto-generation
+2
option
Synchronous section
+3
acceleration ratio
+4
Sheet length
+5
+6
Sheet
synchronization
+7
width
+8
Synchronous axis
length
+9
+10
Synchronous
position adjustment
+11
+12
Acceleration/
deceleration width
+13
+14
Number of cutter
Asynchronous speed
+15
result
(2) Device assignment of the cam auto-generation data for the rotary cutter cam
When the synchronous position adjustment is set to 0, the cam pattern of which
the sheet center is in the synchronous section is created.
Description
Set the cam resolution for generating the cam.
• Select the trapezoidal acceleration/deceleration system
or the S-curve acceleration/deceleration system with bit
0.
• Select the diameter or the cycle length for the
synchronous axis length with bit 1.
• Set 0 for bits 2 to 15.
Set when the synchronous speed in the synchronous
section needs to be adjusted.
The speed is "Synchronous speed  (100% +
Acceleration ratio)" in the synchronous section.
Set the sheet length.
• Set the sheet synchronization width (seal width).
• When the synchronous speed section for retracting is
required in front of and behind the sheet synchronization
width, add the retracting width.
• Set the rotary cutter axis length.
• When the synchronous axis length of the auto-
generation option is set to the diameter, "Cycle length =
setting value × ".
• When the synchronous axis length of the auto-
generation option is set to the cycle length, "Cycle length
= setting value".
• Set the position adjustment of the synchronous section.
- : The synchronous section is adjusted to the sheet
start side.
0 : The center of the sheet is in the synchronous section.
+ : The synchronous section is adjusted to the sheet end
side.
• Set the value within one-half of the sheet length.
• Set the sheet width (one side) of the
acceleration/deceleration area.
• When a negative value is set, the
acceleration/deceleration width is determined to be the
maximum.
Set the number of cutter.
When the cam auto-generation is successfully performed,
the asynchronous speed is stored as the ratio to the
synchronous speed.
5 - 174
Range
256/512/1024/2048/4096/
8192/16384/32768
• Bit 0 ........ Acceleration/deceleration system
0: Trapezoidal acceleration/
deceleration
1: S-curve acceleration/
deceleration
• Bit 1 ........ Synchronous axis length setting
0: Diameter
1: Cycle length
-5000 to 5000[0.01%]
1 to 2147483647
[(Optional) Same units]
1 to 2147483647
[(Optional) Same units]
For diameter setting
1 to 680000000
For cycle length setting
1 to 2147483647
[(Optional) Same units]
-1073741823 to 1073741823
[(Optional) Same units]
0 to 2147483647
[(Optional) Same units]
(Note): For a value other than the above, the
acceleration/deceleration width is
determined to be the maximum.
1 to 256
0 to 65535[0.01 times]