Reset A Status Storage Device : Mvfin - Mitsubishi Electric Melsec Q Series Programming Manual

Motion controller (sv13/sv22)
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

5 OPERATION CONTROL PROGRAMS

5.15.7 Reset a status storage device : MVFIN

Format
[Usable data]
Setting
16-bit
data
Bit device
integer
type
(S)
[Setting data]
Setting data
[Functions]
[Errors]
[Program examples]
MVFIN(S)
(Note-1)
Word device
64-bit
32-bit
floating
integer
point
type (L)
type (F)
Vision system (camera) No. to reset the status
(S)
(1) The status storage device value set in the Ethernet communication line setting
parameter specified with (S) is 20 (reception enabled). (Refer to APPENDIX 3.2.)
(2) When a trigger is issued to the vision system, the status storage device is reset by
MVFIN instruction in advance, and the process completion for trigger needs to be
detected.
(1) An operation error will occur if:
• The (S) data is outside the range of 1 to 8.
• The vision system specified with (S) has not been logged on.
• The vision system parameter setting (Refer to APPENDIX 3.2.) is different from
the setting on the vision system.
• The status storage device value set in the Ethernet communication line setting
parameter is not 20 (reception enabled), 40 (Image data reception completed),
or 50 (value cell reception completed).
(1) Program which resets the status storage device for the vision system (camera) 1
MVFIN K1
Usable Data
Constant
16-bit
32-bit
Coasting
integer
integer type
timer
type (K/H)
(K/H, L)
Description
storage device (1 to 8)
5 - 140
F/FS
Number of basic steps
Bit
64-bit
Calculation
conditional
floating
expression
expression
point
type (K)
(Note-1): The special register (SD) cannot be used.
Data type of result
G
2
Comparison
conditional
expression
: Usable

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents