17 07 19 Removing and installing oil temperature
sensor
Removal
Installation
top of page
Removal
1. Undo fastening screw M6x34 on the air cleaner housing (A/f 13).
2. Undo hose clamp between the air cleaner housing and intake
manifold.
3. Pull off electrical wire connector of the hot film mass air flow
meter:
•
To do this, push the plug downwards and press on the grooved surface at the sides.
•
Then pull the connector up and off.
Open the omega clip on the left side of the air cleaner housing and take out the electrical wire of the
•
hot film mass air flow meter.
•
Re−close the omega clip for the removal (risk of breakage)
4. Tilt the complete air cleaner housing 90° upwards and remove
rearwards.
17 07 19 Removing and installing oil temperature sensor