Remove the activated carbon filter lead. To do so, disconnect the plug connection on the bleeder valve
−arrow− and disconnect the coupling on the pressure pipe.
10. Undo the six upper screw−type hose clamps on the rubber sleeves of the intake distributors.
11. Disconnect all vacuum leads at the four−way branch piece.
Note
•
All rubber sleeves must be sealed (foreign objects)!
12. Pull the intake distributor out of the rubber sleeves and lay to one side.
top of page
Installing intake distributor
Note
Check rubber sleeves and replace, if necessary!
•
1. Coat the inside of the rubber sleeves slightly with Vaseline. Place intake distributor into rubber
sleeves and press into place evenly as far as the stops without tilting.
2. Connect all the vacuum leads at the four−way branch
piece.
3. Tighten the six upper screw−type hose clamps on the rubber
sleeves.
Installing intake distributor
einordnung