12. Unscrew drain plug −A− and drain ATF.
13. Remove ATF pan (loosen screws crosswise).
14. Remove ATF filter.
15. Place selector lever in position − P − and unscrew the fastening screws for the control unit.
top of page
Installing the electrohydraulic control unit
Install in reverse order, observing the following points:
1. Place selector lever in position − P − and place the control unit carefully in position. The selector
valve must engage in the driver of the notched plate.
2. First tighten screws for the control unit hand tight. Then
tighten.
Tightening torque: 8 Nm (6 ftlb.).
Installing the electrohydraulic control unit
einordnung