Table 17 Output codes 10
Code
Displayed Name
Description
10-010 Fuser Web Motor
Energizes the fuser web motor
(MOT10-010)
10-030 Invert Mot Fwd
Energizes the inverter motor
Slow
(MOT10-030) forward at process
speed.
10-035 Invert Mot Rev
Energizes the inverter motor
Slow
(MOT10-030) in reverse at pro-
cess speed.
10-040 Invert Mot Rev Dup Energizes the inverter motor
(MOT10-030) in reverse at duplex
speed.
10-045 Inverter Path Sol
Energizes the invert path solenoid
(SOL10-045). When de-energized
sheets are fed to the inverter
10-050 Inverter Nip Sol
Energizes the inverter nip solenoid
(SOL10-050). When de-energized
the nip is open
10-055 Tri Roll Split Nip
Energizes the tri roll split nip sole-
Sol
noid (SOL10-055). When de-ener-
gized the nip is open
10-065 Vac Transport Fan Energizes the vacuum transport
fan in the short paper path assem-
bly
Table 18 Output codes 11
Code
Displayed Name
Description
11-000 Transport Motor 1
Energizes the LCSS transport Motor 1,
and HCSS BM and HVF transport motor
1A and Transport motor 1B (MOT11-000)
11-001 Transport Motor 2
Energizes the LCSS, HCSS BM and HVF
transport motor 2 (MOT11-001)
11-002 Diverter Solenoid
Energizes the LCSS, HVF diverter gate
solenoid, HCSS BM and HVF BM upper
diverter solenoid (SOL11-002)
11-003 Tamp Mot Front
Energizes the LCSS, HCSS BM and HVF
Home
front tamper motor (MOT11-003) to the
home position.
11-004 Tamp Mot Rear
Energizes the LCSS, HVF and HCSS BM
Home
rear tamper motor (MOT11-004) to home
position
11-005 Tamp Mot Front
Energizes the LCSS, HVF and HCSS BM
Move
front tamper motor (MOT11-003) move
inbound.
11-006 Tamp Mot Rear
Energizes the LCSS, HVF and HCSS BM
Move
rear tamper motor (MOT11-004) move
inbound.
General Procedures & Information
dC330
General
Code
Displayed Name
On/off. 90 seconds timeout
11-007 Tampers to A4LEF Moves the LCSS and HCSS BM tampers
On/off. 90 seconds timeout
11-008 Tampers to
8.5x11LEF
11-009 Tamper Motor
On/off. 90 seconds timeout
Cycle
11-010 CC Eject Roll Motor Energizes the HVF and HCSS BM com-
On/off. 90 seconds timeout
11-011 CC Hold Solenoid
11-013 CC motor Step Up
On/off. 5 seconds timeout
11-014 CC Motor Move Up Energizes the HCSS compiler carriage
On/off. 5 seconds timeout
11-015 CC Motor Step
Down
On/off. 5 seconds timeout
11-016 CC Motor Move
Down
On/off. 90 seconds timeout
11-020 Ejector Motor
Home
11-021 Ejector Motor Move Energizes the LCSS, ejector motor
11-023 Ejector Motor Cycle Energizes the LCSS, HVF and HCSSBM
General
On/off. 90 seconds
11-024 Paddle Roll Motor
timeout
Home
On/off. 90 seconds
11-025 Paddle Roll Motor
timeout
Run
On/off. 5 seconds
timeout
11-026 Paddle Roll Mot
Rev
On/off. 5 seconds
timeout
11-027 Paddle Unit Motor
On/off. 5 seconds
11-030 Bin 1 Elev. Mot
timeout
Home
On/off. 5 seconds
11-031 Bin 1 Elev. Mot Up
timeout
On/off. 5 seconds
timeout
August 2007
6-316
Table 18 Output codes 11
Description
General
On/off. 5 seconds
to A4LEF position.
timeout
Move the LCSS and HCSS BM tampers to
On/off. 5 seconds
8.5"x11" LEF position.
timeout
Cycles the LCSS tampers in and out until
On/off. 90 seconds
time-out or stop.
timeout
On/off. 90 seconds
piler carriage eject roll motor (MOT11-010)
timeout
Energizes the HCSS BM compiler carriage
On/off. 5 seconds
tray hold solenoid (SOL11-011)
timeout
Energizes the HCSS ''''compiler carriage
On/off. 5 seconds
elevator motor (MOT11-013)
timeout
On/off. 15 seconds
elevator motor (MOT11-013) to the upper
timeout
limit switch
Energizes the HCSS compiler carriage
On/off. 5 seconds
elevator motor (MOT11-013)
timeout
Energizes the HCSS compiler carriage
On/off. 15 seconds
elevator motor (MOT11-013) to the lower
timeout
limit switch
Energizes the LCSS, ejector motor
On/off. 5 seconds
(MOT11-020) to the home position
timeout
On/off. 5 seconds
(MOT11-020) to the out position
timeout
On/off. 90 seconds
ejector motor (MOT11-020) cycle routine
timeout
until timeout or stop.
Energizes the LCSS and HCSS BM pad-
On/off. 15 seconds
dle roll motor (MOT11-024) to the home
timeout
position
Energizes the LCSS, HVF and HCSS BM
On/off. 15 seconds
paddle roll motor (MOT11-025) until time-
timeout
out or stop
Energizes the LCSS paddle roll motor
On/off. 15 seconds
(MOT11-024) in reverse to actuate safety
timeout
gate.
Energizes the HVF paddle unit motor
On/off. 90seconds
(MOT11-027) to lift / lower paddle unit
timeout
Energizes the LCSS, HVF and HCSS BM
On/off. 15 seconds
bin 1 elevate motor (MOT11-030) to the
timeout
home position.
Energizes the LCSS, HVF and HCSS BM
On/off. 15 seconds
bin 1 elevate motor (MOT11-030) by incre-
timeout
ments up