Table 4 Peru NVM values
Location NVM Name
NVM Description
20-548
FaxCongest1Bre
Congest 1 break max 2
akMax2
20-552
Congt1FlgDetctP
Congest 1 flag detection
erfd2
performed 2
20-553
FaxCongest1Ma
Congest 1 make min 3
keMin3
20-554
FaxCongest1Ma
Congest 1 make max 3
keMax3
20-555
FaxCongest1Ma
Congest 1 make hole 3
keHole3
20-556
FaxCongest1Bre
Congest 1 break min 3
akMin3
20-557
FaxCongest1Bre
Congest 1 break max 3
akMax3
20-562
FaxCED1FiltrSta
CED 1 Filter stage 1 A1
ge1A1
20-563
FaxCED1FiltrSta
CED 1 Filter stage 1 A2
ge1A2
20-564
FaxCED1FiltrSta
CED 1 Filter stage 1 A3
ge1A3
20-565
FaxCED1FiltrSta
CED 1 Filter stage 1 B1
ge1B1
20-566
FaxCED1FiltrSta
CED 1 Filter stage 1 B2
ge1B2
20-567
FaxCED1FiltrSta
CED 1 Filter stage 2 A1
ge2A1
20-568
FaxCED1FiltrSta
CED 1 Filter stage 2 A2
ge2A2
20-569
FaxCED1FiltrSta
CED 1 Filter stage 2 A3
ge2A3
20-570
FaxCED1FiltrSta
CED 1 Filter stage 2 B1
ge2B1
20-571
FaxCED1FiltrSta
CED 1 Filter stage 2 B2
ge2B2
20-572
FaxCED1LwPas
CED 1 Low Pass Feedback Range = 1 to 65535
sFeedbck
20-573
FaxCED1LowPa
CED 1 Low Pass Gain
ssGain
20-585
FaxCED1IdxNex
CED 1 idx next cell 1
tCell1
20-616
IntDtone1LwPss
International Dtone 1 Low
Fdback
Pass Feedback
20-617
IntDtone1LwPss
International Dtone 1 Low
Gain
Pass Gain
WorkCentre 5687 Family
Value
Default
Location NVM Name
Range = 0 to 10000 ms
350
20-621
Is this the last detection
1
pattern? Range = 0 to 1
20-628
Range = 0 to 10000 ms
150
20-632
Range = 0 to 10000 ms
350
20-642
Range = 0 to 10000 ms
30
Range = 0 to 10000 ms
150
20-643
Range = 0 to 10000 ms
350
20-644
Range = 1 to 65535
489
20-645
20-646
Range = 1 to 65535
64562
20-682
Range = 0 to 65535
488
20-684
Range = 1 to 65535
57167
20-685
Range = 1 to 65535
49479
20-686
Range = 1 to 65535
489
20-687
Range = 1 to 65535
846
20-688
Range = 1 to 65535
488
20-693
Range = 1 to 65535
57113
20-694
Range = 1 to 65535
49479
20-695
32560
20-696
Range = 1 to 65535
207
20-697
Index of next pattern.
255
Range = 0 to 2
20-692
Range = 1 to 65535
32560
20-711
Range = 1 to 65535
207
August 2007
6-263
Table 4 Peru NVM values
NVM Description
TimeBefore-dial
Determines pause time
before dial (blind mode) or
dial tone detection time out.
T0Timeout
CED detect time from end of
dial to call clear down.
FaxTxSignalLev
Fax modem Tx level for
Ln1Ln2
line1 and 2
FaxDelayBe-
Delay between faxes
tweenFaxes
Line 1 Imped-
Line 1 impedance
ance
Line 2 Imped-
Line 2 impedance
ance
Line 1 Current
Line 1 Current
Line 2 Current
Line 2 Current
Ring2NumCellPa
Ring 2 number cell pattern
ttern
FaxRing2MakeM
Ring 2 make min 1
in1
FaxRing2MakeM
Ring 2 make max 1
ax1
FaxRing2MakeH
Ring 2 make hole 1
ole1
FaxRing2Break
Ring 2 break min 1
Min1
FaxRing2Break
Ring 2 break max 1
Max1
FaxRing2MakeM
Ring 2 make min 2
in2
FaxRing2MakeM
Ring 2 make max 2
ax2
FaxRing2MakeH
Ring 2 make hole 2
ole2
FaxRing2Break
Ring 2 break min 2
Min2
FaxRing2Break
Ring 2 break max 2
Max2
Ring2FlgDetectP
Ring 2 flag detection per-
erfd1
formed 1
Dtone1FilterStag
Dtone 1 Filter stage 1 A1
e1A1
Value
Default
Range = 0 to 255. 1 =
5
100 ms
Range = 0 to 255. (1
50
second step)
Range = 0 to 15 in -1dB
15
steps. 0 = 0dBm, 15 = -
15dBm
Guard delay between
5
outgoing faxes. Range =
1 to 10 seconds
0 = complex 1 = 600
1
ohms
0 = complex
1 = 600
1
ohms
0 = off 1 = on
0
0 = off 1 = on
0
Number of ring pattern
1
detectors. Range = 0 to 3
Range = 0 to 10000 ms
500
Range = 0 to 10000 ms
1500
Range = 0 to 10000 ms
130
Range = 0 to 10000 ms
3000
Range = 0 to 10000 ms
5000
Range = 0 to 10000 ms
500
Range = 0 to 10000 ms
1500
Range = 0 to 10000 ms
130
Range = 0 to 10000 ms
3000
Range = 0 to 10000 ms
5000
Is this the last detection
0
pattern? Range = 0 to 1
Range = 0 to 65535
829
General Procedures & Information
dC131h

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wc5632fWc5545fWc5675fWc5645fWc5687fWc5655f

Table of Contents