Main Menu
Table of Contents
Shift Fork, Synchro
Sleeve
Clearance Inspection
1.
Measure the clearance between each shift fork and
its matching synchro sleeve..
2.
If the clearance exceeds the service limit, measure
the width of the shift fork fingers.
If the width of the shift fork fingers is less than the
standard, replace the shift fork with a new one.
If the width of the shift fork fingers is within the
standard, replace the synchro sleeve with a new
one. The synchro sleeve and synchro hub should be
replaced as a set.