Make A Second Set Of Measurements Using Automatic Null Value Selection; Typical Response: +0.00000000E+00,+0.01420000E+00 - Keysight Truevolt Series Operating And Service Manual

Digital multimeters
Table of Contents

Advertisement

SCPI Programming Reference
[SENSe:]TEMPerature:NULL:VALue:AUTO {ON|1|OFF|0}
[SENSe:]TEMPerature:NULL:VALue:AUTO?
Enables or disables automatic null value selection for temperature measurements.
Parameter
{ON|1|OFF|0}. Default: OFF.
Configure temperature measurements, using the null function to subtract 25° from them. Make and read
two measurements:
CONF:TEMP RTD
TEMP:NULL:STAT ON;VAL 25>
SAMP:COUN 2
READ?
Typical Response: +1.04530000E+00,+1.04570000E+00

Make a second set of measurements using automatic null value selection:

TEMP:NULL:VAL:AUTO ON
READ?

Typical Response: +0.00000000E+00,+0.01420000E+00

When automatic reference selection is ON, the first measurement made is used as the null value for all
l
subsequent measurements.
value selection will be disabled.
When automatic null value selection is disabled (OFF), the null value is specified by:
l
ature:NULL:VALue.
The instrument enables automatic null value selection when the null function is enabled
l
([SENSe:]TEMPerature:NULL:STATe
This parameter is set to its default value after a Factory Reset (*RST), Instrument Preset
l
(SYSTem:PRESet), or CONFigure function.
362
0 (OFF) or 1 (ON)
[SENSe:]TEMPerature:NULL:VALue
ON).
Typical Return
is set to this value. Automatic null
Keysight True volt Series Operating and Service Guide