Making MSR Measurements

Setting Up and Making a Measurement

Setting Up and Making a Measurement

Making the Initial Signal Connection

Before connecting a signal to the analyzer, make sure the analyzer can safely
accept the signal level provided. The signal level limits are marked next to the RF
Input connectors on the front panel.
See the Input Key menu for details on selecting input ports, and the AMPTD Y
Scale menu, for details on setting internal attenuation to prevent overloading
the analyzer.

Using Analyzer Mode and Measurement Presets

To set your current measurement mode to a known factory default state, press
Mode Preset. This initializes the analyzer by returning the mode setup and all
of the measurement setups in the mode to the factory default parameters.
To preset the parameters that are specific to an active, selected measurement,
press Meas Setup, Meas Preset. This returns all the measurement setup
parameters to the factory defaults, but only for the currently selected
measurement.

The 3 Steps to Set Up and Make Measurements

All measurements can be set up using the following three steps. The sequence
starts at the Mode level, is followed by the Measurement level, then finally, the
result displays may be adjusted.
Table 2-1
The 3 Steps to Set Up and Make a Measurement
Step
1. Select and Set Up the
Mode
2. Select and Set Up the
Measurement
10
Action
Mode
a. Press
b. Press a mode key, like
Spectrum Analyzer, LTE FDD
& LTE-A FDD
MSR
or
Mode Preset
c. Press
.
Mode Setup
d. Press
Meas.
a. Press
b. Select the specific
measurement to be performed.
Meas Setup
c. Press
Notes
All licensed, installed modes available
are shown under the
Mode Setup
Using
required adjustments to the mode
.
settings. These settings will apply to all
measurements in the mode.
The measurement begins as soon as any
required trigger conditions are met. The
resulting data is shown on the display or
is available for export.
Use Meas Setup to make any required
adjustment to the selected measurement
settings. The settings only apply to this
measurement.