Compatible SCPI Commands
Supported SCPI Commands
Preset
State Saved
Min
Max
[SENSe<1|2>:]POWer:ACHannel:PRESet ACPower | CPOWer | MCACpower | OBANdwidth |

OBWidth | CN | CN0

Adjusts the frequency span, the measurement bandwidths including the required detector for the number
of channels, the channel bandwidths, and the channel spacings selected in the active power
measurement. If required, switches on the adjacent-channel power measurement prior to the adjustment.
Remote Command
Example
Remote Command Notes
State Saved
Range
[SENSe<1|2>:]POWer:ACHannel:PRESet:RLEVel
Adjusts the reference level to the measured channel power. If required, switches on the adjacent channel
power measurement.
This command is accepted, but takes no action and reports no error.
Remote Command
Example
Remote Command Notes
[SENSe<1|2>:]POWer:BANDwidth|BWIDth 10 to 99.9PCT
Specifies the power percentage with respect to the total power.
Remote Command
Example
Remote Command Notes
Preset
State Saved
146
This Manual:http://www.manuallib.com/agilent/n9062a-signal-analyzer-user-guide.html
1
Saved in instrument state.
1
2
[:SENSe]:POWer:ACHannel:PRESet
ACPower|CPOWer|MCACpower|OBANdwidth|OBWidth|CN|CN0
SENS:POW:ACH:PRES ACP
FSE, FSP, FSU
No
ACPower | CPOWer | MCACpower | OBANdwidth | OBWidth | CN | CN0
[:SENSe]:POWer:ACHannel:PRESet:RLEVel
SENS:POW:ACH:PRES:RLEV
FSP, FSU
[:SENSe]:POWer:BANDwidth|BWIDth <real>
[:SENSe]:POWer:BANDwidth|BWIDth?
POW:BAND 99.0
POW:BAND?
FSP, FSU
99PCT
Saved in instrument state.