Compatible SCPI Commands
Supported SCPI Commands
Remote Command Notes
Preset
State Saved
Min
Max
[SENSe<1|2>:]POWer:ACHannel:SPACing:ACHannel 100 Hz to 2000 MHz
Specifies the channel spacing of the adjacent channel to the TX channel. At the same time, the spacing of
alternate adjacent channels 1 and 2 is set to double or triple the entered value.
This command is available only in the frequency domain (span > 0).
Remote Command
Example
Remote Command Notes
Preset
State Saved
Min
Max
[SENSe<1|2>:]POWer:ACHannel:SPACing:ALTernate<1|2> 100 Hz to 2000 MHz
Specifies the spacing between the first (ALTernate1) or second alternate adjacent channel (ALTernate2)
and the TX channel.
Remote Command
Example
Remote Command Notes
Preset
State Saved
Min
Max
[SENSe<1|2>:]POWer:ACHannel:TXCHannel:COUNt 1 | 2 | 3 | 4
Specifies the number of carrier signals. This command is only available for multicarrier channel and
142
This Manual:http://www.manuallib.com/agilent/n9062a-signal-analyzer-user-guide.html
FSE, FSP, FSU
20 kHz
Saved in instrument state.
100 Hz
2 GHz
[:SENSe]:POWer:ACHannel:SPACing:ACHannel <freq>
[:SENSe]:POWer:ACHannel:SPACing:ACHannel?
POW:ACH:SPAC:ACH 33kHz
FSE, FSP, FSU
20KHz
Saved in instrument state.
100Hz
2000MHz
[:SENSe]:POWer:ACHannel:SPACing:ALTernate[1]|2 <freq>
[:SENSe]:POWer:ACHannel:SPACing:ALTernate[1]|2?
POW:ACH:SPAC:ALT1 100kHz
FSE, FSP, FSU
40000|60000
Saved in instrument state.
100Hz
2000MHz