Agilent Technologies MXA N9020A User Manual (175 pages)
Signal Analyzer, EMI Receiver
Brand:
Agilent Technologies
| Category:
Measuring Instruments
| Size: 0.81 MB
Table of Contents
Table of Contents
6
1 Getting Started
16
What Does the Agilent N9062A & W9062A SCPI Language Compatibility Application Do
17
Documentation for the N9062A & W9062A SCPI Language Compatibility Application
18
Signal Analyzers with N9062A/W9062A
18
Signal Analyzer Updates
18
SCPI Language Compatibility Application General Rules and Limitations
19
Couplings
19
Data Formats
19
Markers
19
Numeric Ranges
19
Remote Control
19
Returning Data
19
Units
20
Status System & SRQ
20
Supported Commands and Queries
21
Unsupported Commands and Queries
21
Hardware and Firmware Requirements For N9062A/W9062A
22
Installing the N9062A & W9062A SCPI Language Compatibility Application
24
License for N9062A/W9062A
24
Installation
24
Licensing
24
License Installation Procedure over USB
25
Verify the Installation
25
Running Software that Requires SCPI Commands
26
Service and Calibration
27
2 Front Panel Operations
28
Selecting SCPI Language Compatibility Mode
29
Selecting SCPI Language Compatibility Mode as the Power-On Application
30
Mode Setup
31
Selecting Compatibility Model
31
R&S Fse
32
R&S Fsp
32
R&S Fsu
32
Selecting Mode IDN Response
33
Compatibility Model
34
System IDN Response
34
User IDN Response
34
Restore Mode Defaults
35
Send Commands
36
3 Compatible SCPI Commands
39
SCPI Summary Table
39
Agilent N9062A/W9062A Supported IEEE SCPI Commands
56
Supported SCPI Commands
58
Mode Selection
58
Mode Setup
58
Compatibility Mode
58
R&S Fse
59
R&S Fsp
59
R&S Fsu
59
Mode IDN Response
59
Compatibility Model
60
System IDN Response
60
User IDN Response
60
Abort Subsystem
60
Abort
61
Calculate:deltamarker Subsystem
61
Calculate<1|2>:Deltamarker<1
61
Calculate<1|2>:Deltamarker<1
62
Calculate<1|2>:Deltamarker<1
63
Calculate<1|2>:Deltamarker<1
64
Calculate<1|2>:Deltamarker<1
65
Calculate<1|2>:Deltamarker<1
66
Numeric_Value
66
Calculate<1|2>:Deltamarker<1
67
Calculate<1|2>:Deltamarker<1
68
Calculate:limit Subsystem
68
Calculate<1|2>:Limit<1
68
Calculate<1|2>:Limit<1
69
Ampere| DB | DEG | RAD | S | HZ | PCT | UNITLESS
69
Calculate<1|2>:Limit<1
70
Calculate<1|2>:Limit<1
71
Calculate<1|2>:Limit<1
72
Calculate:limit:espectrum Subsystem
72
Calculate<1|2>:Limit<1
73
Calculate:limit:acpower Subsystem
73
Calculate<1|2>:Limit<1
74
Calculate<1|2>:Limit<1
75
Calculate<1|2>:Limit<1
76
Calculate<1|2>:Limit<1
77
Calculate:limit:control Subsystem
78
Calculate<1|2>:Limit<1
78
Calculate<1|2>:Limit<1
79
Calculate:limit:lower Subsystem
80
Calculate<1|2>:Limit<1
80
Calculate<1|2>:Limit<1
81
Calculate<1|2>:Limit<1
82
Calculate:limit:upper Subsystem
83
Calculate<1|2>:Limit<1
83
Calculate<1|2>:Limit<1
84
Calculate<1|2>:Limit<1
85
Calculate<1|2>:Limit<1
86
Calculate:marker Subsystem
87
Calculate<1|2>:Marker<1
87
Calculate<1|2>:Marker<1
88
Calculate<1|2>:Marker<1
89
Calculate<1|2>:Marker<1
90
Calculate<1|2>:Marker<1
91
Calculate<1|2>:Marker<1
92
Calculate<1|2>:Marker<1
93
Calculate:marker:function Subsystem
94
Calculate<1|2>:Marker<1
94
Calculate<1|2>:Marker<1
95
Calculate<1|2>:Marker<1
96
Calculate<1|2>:Marker<1
97
Calculate:marker:function:power Subsystem
97
Calculate<1|2>:Marker<1
98
Calculate:statistics Subsystem
98
Calculate:statistics:apd[:State] on | off
98
Calculate:statistics:ccdf[:State] on | off
98
Calculate:statistics:ccdf:X<1
99
Calculate:statistics:nsamples <100
99
Calculate:statistics:scale:auto ONCE
100
Calculate:statistics:scale:X:rlevel -130Dbm to 30Dbm
100
Calculate:statistics:scale:X:range 10Db to 200Db
100
Calculate:statistics:scale:y:upper 1E-8 to 1.0
101
Calculate:statistics:scale:y:lower 1E-9 to 0.1
101
Calculate:statistics:preset
101
Calculate:statistics:result<1
102
Calculate:threshold Subsystem
102
Calculate<1|2>:Dline<1|2> Minimum
102
Calculate<1|2>:Dline<1|2>:State on | off
102
Calculate<1|2>:Threshold Minimum to Maximum (Depending on Current Unit)
103
Calculate<1|2>:Threshold:state on | off
103
Calculate<1|2>:Fline<1|2> 0
103
Calculate<1|2>:Fline<1|2>:State on | off
103
Calculate<1|2>:Tline<1|2> 0
104
Calculate<1|2>:Tline<1|2>:State on | off
104
Calculate:unit Subsystem
104
Calculate<1|2>:Unit:power DBM | V | a | W | DB | PCT | UNITLESS |DBPW | WATT | DBUV |DBMV | VOLT | DBUA | Ampere
104
Calibration Subsystem
106
Calibration:state on | off
106
Calibration[:All]
106
Display Subsystem
106
Display:annotation:frequency on | off
107
Display:format Single | Split
107
Display:logo on | off
107
Display:cmap<1 to 26>:Default<1|2
108
Display:cmap<1 to 26>:HSL <Hue>,<Sat>,<Lum
108
Display:psave:holdoff 1 to 60
108
Display:psave[:State] on | off
108
Display:cmap<1 to 26>:Pdefined Black | BLUE | Brown | Green | CYAN | RED | Magenta | Yellow | White | Dgray | Lgray | Lblue | Lgreen | Lcyan | LRED | Lmagenta
109
Display[:Window<1|2>]:Select
109
Display[:Window<1|2>]:Size Large|Small
110
Display[:Window<1|2>]:Text:state on | off
110
Display[:Window<1|2>]:Text[:Data] <String
110
Display[:Window<1|2>]:Time on | off
111
Display[:Window<1|2>]:Trace<1 to 3>:Y[:Scale] 10Db to 200Db
111
Display[:Window<1|2>]:Trace<1 to 3>:Y[:Scale]:Mode Absolute | Relativ
111
Display[:Window<1|2>]:Trace<1 to 3>:Y[:Scale]:Rlevel
112
Display[:Window<1|2>]:Trace<1 to 3>:Y[:Scale]:Rlevel:offset
112
Display[:Window<1|2>]:Trace<1 to 3>:Y:spacing Linear | Logarithmic| LDB
113
Display[:Window<1|2>]:Trace<1 to 3>:Y[:Scale]:Pdivision
113
Display[:Window<1|2>]:Trace<1 to 3>[:State] on | off
114
Format Subsystem
114
Format[:Data]
114
Hcopy Subsystem
115
Hcopy:abort
115
Hcopy:cmap<1 to 26>:Default1|2|3
115
Hcopy:cmap<1 to 26>:HSL <Hue>,<Sat>,<Lum
115
Hcopy:cmap<1 to 26>:Pdefined Black | BLUE | Brown | Green | CYAN | RED | Magenta | Yellow | White | Dgray | Lgray | Lblue | Lgreen | Lcyan | LRED | Lmagenta
116
Hcopy:destination<1|2> <String
116
Hcopy:device:color ON|OFF
116
Hcopy:device:language<1|2> GDI | WMF | EWMF | BMP
117
Hcopy[:Immediate<1|2>]
117
Hcopy:item:all
117
Hcopy:item:window<1|2>:Table:state on | off
117
Hcopy:item:window<1|2>:Text <String
118
Hcopy:item:window<1|2>:Trace:state on | off
118
Hcopy:page:orientation<1|2> Landscape | Portrait
118
Initiate Subsystem
119
Initiate<1|2>:Continuous on | off
119
Initiate<1|2>:Conmeas
119
Initiate<1|2>[:Immediate]
119
Input Subsystem
119
Input<1|2>:Attenuation
119
Input<1|2>:Attenuation:auto
120
Input<1|2>:Eatt
120
Input<1|2>:Eatt:auto
121
Input<1|2>:Eatt:state
121
Input<1|2>:Impedance
121
Input<1|2>:Gain:state
122
Instrument Subsystem
122
Instrument[:Select] Sanalyzer | Ddemod | Ademod | MGSM | Wcdpower|Bwcdpower |Mwcdpower | BC2K| BDO
122
Instrument:nselect <Numeric Value
122
Mmemory Subsystem
124
Mmemory:catalog? <Path
124
Mmemory:cdirectory <Directory_Name
124
Mmemory:copy <File_Source>,<File_Destination
124
Mmemory:data <File_Name>[,<Block_Data>]
125
Mmemory:delete <File_Name
125
Mmemory:initialize <Msus
125
Mmemory:load:state 1,<File_Name
125
Mmemory:load:auto 1,<File_Name
126
Mmemory:mdirectory <Directory_Name
126
Mmemory:move <File_Source>,<File_Destination
126
Mmemory:msis <Device
126
Mmemory:name <File_Name
126
Mmemory:rdirectory <Directory_Name
127
Mmemory:store<1|2>:State 1,<File_Name
127
Mmemory:store<1|2>:Trace <1
127
Mmemory:clear:state 1,<File_Name
127
Mmemory:clear:all
128
Mmemory:select[:Item]:Hwsettings on | off
128
Mmemory:select[:Item]:Trace[:Active] on | off
128
Mmemory:select[:Item]:Lines:all on | off
128
Mmemory:select[:Item]:Scdata on | off
129
Mmemory:select[:Item]:Transducer:all on | off
129
Mmemory:select[:Item]:All
129
Mmemory:select[:Item]:None
130
Mmemory:select[:Item]:Default
130
Mmemory:comment <String
130
Sense:average Subsystem
130
[Sense<1|2>:]Average:count 0 to 32767
130
Sense:bandwidth Subsystem
131
[Sense<1|2>:]Average:type Video | Linear
131
[Sense<1|2>:]Average[:State<1 to 3>] on | off
131
[Sense<1|2>:]Bandwidth|Bwidth[:Resolution] <Numeric_Value
132
[Sense<1|2>:]Bandwidth|Bwidth[:Resolution]:Auto on | off
132
[Sense<1|2>:]Bandwidth|Bwidth[:Resolution]:Ratio 0.0001 to 1
132
[Sense<1|2>:]Bandwidth|Bwidth:video 1Hz to 10Mhz
133
[Sense<1|2>:]Bandwidth|Bwidth[:Resolution]:Type Normal | FFT | Cfilter | RRC
133
Sense:correction Subsystem
134
[Sense<1|2>:]Bandwidth|Bwidth:video:auto on | off
134
[Sense<1|2>:]Bandwidth|Bwidth:video:ratio 0.01 to 1000
134
[Sense<1|2>:]Correction:egain:input[:Magnitude] -200
134
[Sense<1|2>:]Correction:transducer:select <Name
135
[Sense<1|2>:]Correction:transducer:unit <String
135
[Sense<1|2>:]Correction:transducer:comment <String
136
[Sense<1|2>:]Correction:transducer:data <Freq>,<Level
136
[Sense<1|2>:]Correction:transducer:scaling Linear | Logarithmic
136
[Sense<1|2>:]Correction:transducer:delete
137
[Sense<1|2>:]Correction:transducer:view on | off
137
[Sense<1|2>:]Correction:transducer[:State] on | off
137
Qpeak
138
Sense:detector Subsystem
138
Sense:frequency Subsystem
138
[Sense<1|2>:]Detector<1
138
[Sense<1|2>:]Detector<1 to 3>[:Function]:Auto on | off
138
[Sense<1|2>:]Frequency:center 0 to Fmax
139
[Sense<1|2>:]Frequency:center:step 0 to Fmax
139
[Sense<1|2>:]Frequency:center:step:link SPAN | RBW | off
139
[Sense<1|2>:]Frequency:center:step:link:factor 1 to 100 PCT
140
[Sense<1|2>:]Frequency:span 0 to Fmax
140
[Sense<1|2>:]Frequency:span:full
140
[Sense<1|2>:]Frequency:start 0 to Fmax
141
[Sense<1|2>:]Frequency:stop 0 to Fmax
141
Sense:power Subsystem
142
[Sense<1|2>:]Frequency:mode CW | Fixed | Sweep
142
[Sense<1|2>:]Frequency:offset
142
[Sense<1|2>:]Power:achannel:spacing:channel 100 Hz to 2000 Mhz
142
[Sense<1|2>:]Power:achannel:spacing:achannel 100 Hz to 2000 Mhz
143
[Sense<1|2>:]Power:achannel:spacing:alternate<1|2> 100 Hz to 2000 Mhz
143
[Sense<1|2>:]Power:achannel:txchannel:count 1 | 2 | 3 | 4
143
[Sense<1|2>:]Power:achannel:acpairs 0 | 1 | 2 | 3
144
[Sense<1|2>:]Power:achannel:bandwidth|Bwidth[:Channel] 100 Hz to 1000 Mhz
144
[Sense<1|2>:]Power:achannel:bandwidth|Bwidth:achannel 100Hz-1000Mhz
145
[Sense<1|2>:]Power:achannel:bandwidth|Bwidth:alternate<1|2> 100 Hz to 1000 Mhz
145
[Sense<1|2>:]Power:achannel:mode Absolute | Relative
145
[Sense<1|2>:]Power:achannel:reference:auto ONCE
146
[Sense<1|2>:]Power:achannel:reference:txchannel:auto Minimum | Maximum | Lhighest
146
[Sense<1|2>:]Power:achannel:reference:txchannel:manual 1 | 2 | 3 | 4
146
[Sense<1|2>:]Power:achannel:preset Acpower | Cpower | Mcacpower | Obandwidth
147
Obwidth | CN | CN0
147
[Sense<1|2>:]Power:achannel:preset:rlevel
147
[Sense<1|2>:]Power:bandwidth|Bwidth 10 to 99.9PCT
147
[Sense<1|2>:]Power:hspeed on | off
148
[Sense<1|2>:]Power:ncorrection on | off
148
[Sense<1|2>:]Power:trace 1 to 3
148
Sense:roscillator Subsystem
149
[Sense<1|2>:]Roscillator:source Internal | External
149
Sense:sweep Subsystem
149
[Sense<1|2>:]Sweep:time 2.5Ms to 16000S (Frequency Domain) | 1Us to 16000S (Time Domain)
149
[Sense<1|2>:]Sweep:time:auto on | off
150
[Sense<1|2>:]Sweep:count 0 to 32767
150
[Sense<1|2>:]Sweep:egate on | off
150
[Sense<1|2>:]Sweep:egate:type Level | EDGE
151
[Sense<1|2>:]Sweep:egate:polarity Positive | Negative
151
[Sense<1|2>:]Sweep:egate:holdoff 125 Ns to 100 S
151
[Sense<1|2>:]Sweep:egate:length 0 to 100 S
152
[Sense<1|2>:]Sweep:egate:source External | Ifpower | Rfpower
152
[Sense<1|2>:]Sweep:points 125 to 8001
152
Status Subsystem
153
Status:operation[:Event]
153
Status:operation:condition
153
Status:operation:enable
153
Status:operation:ptransition
154
Status:operation:ntransition
154
Status:preset
154
Status:questionable[:Event]
155
Status:questionable:condition
155
Status:questionable:enable
155
Status:questionable:ptransition
156
Status:questionable:ntransition
156
Status:questionable:frequency[:Event]
156
Status:questionable:frequency:condition
156
Status:questionable:frequency:enable
157
Status:questionable:frequency:ptransition
157
Status:questionable:frequency:ntransition
157
Status:queue[:Next]
158
System Subsystem
158
System:communicate:gpib[:Self]:Address
158
System:communicate:gpib[:Self]:Rterminator LFEOI | EOI
158
System:date
159
System:display:fpanel on | off
159
System:display:update
159
System:error
160
System:error:list
160
System:error:clear:all
160
System:preset
160
System:time
160
System:version
161
Trace Subsystem
161
Trace:iq Subsystem
161
Trace<1|2>:Iq:data
161
Trace<1|2>[:Data] TRACE1 | TRACE2 | TRACE3 | Spurious | Abitstream | Pwcdp | Ctable, <Block> | <Numeric_Value
161
Trace:iq:srate 15.625Khz to 32Mhz
162
Trace:iq:state on | off
162
Trace<1|2>:Iq:set <Filter Type>,<Rbw>,<Sample Rate>,<Trigger Source>,<Trigger Slope>,<Pretrigger Samples>,<# of Samples
162
Trigger Subsystem
163
Trigger<1|2>[:Sequence]:Level:ifpower -30 to -10DBM
163
Trigger<1|2>[:Sequence]:Level:rfpower
163
Trigger<1|2>[:Sequence]:Source
163
Trigger<1|2>[:Sequence]:Holdoff
164
Trigger<1|2>[:Sequence]:Level:video 0 to 100PCT
164
Trigger<1|2>[:Sequence]:Slope
165
4 A Brief Introduction to the SCPI Language
166
Overview
167
SCPI Language Basics
167
Command Syntax
168
Command Statement Rules Overview
169
Creating Valid Commands
169
Special Characters in Commands
170
Parameters in Commands
170
Block Program Data
172
Variable Parameters
172
Putting Multiple Commands on the same Line
173
SCPI Termination and Separator Syntax
173
Advertisement
Agilent Technologies MXA N9020A Programmer's Manual (115 pages)
Signal Analyzer
Brand:
Agilent Technologies
| Category:
Measuring Instruments
| Size: 0.84 MB
Table of Contents
Table of Contents
5
What Programming Information Is Available
8
Using Embedded Help for Programming
10
Using the Help System on Your PC
10
Help System Features Especially Useful for Programmers
10
Communicating SCPI Using Telnet
13
SCPI Measurement Commands
16
Measurement Group of Commands
16
Common Measurement Commands
20
Status Subsystem (Remote Only Commands)
30
Status Subsystem Description
31
Status Subsystem Commands and Queries
43
2 Programming Fundamentals
71
SCPI Language Basics
71
Command Keywords and Syntax
71
Creating Valid Commands
72
SCPI Language Basics
72
Special Characters in Commands
73
Parameters in Commands
73
Putting Multiple Commands on the same Line
76
Improving Measurement Speed
78
Turn off the Display Updates
78
Use Binary Data Format Instead of ASCII
78
Minimize the Number of GPIB Transactions
79
Consider Using USB or LAN Instead of GPIB
80
Minimize Dut/Instrument Setup Changes
80
Avoid Unnecessary Use of *RST
80
Avoid Automatic Attenuator Setting
80
Avoid Using Rfburst Trigger for Single Burst Signals
81
N9071A: Optimize Your GSM Output RF Spectrum Switching Measurement
82
Ta<N>:Compress
82
Making Power Measurements on Multiple Bursts or Slots? Use Calculate:data<N>:Compress
82
For more Information
84
3 Measurement Synchronization with LXI-B
85
Ieee 1588
85
Synchronizing Time on the MXA and MXG
86
Verifying Time Synchronization on the MXA and MXG
86
Peer to Peer Messaging
87
MXA Instrument Events
87
Outputting LAN Events
87
Configuring LXI Triggers
90
Configuring an LXI Trigger Using SCPI
90
Configuring an LXI Trigger Using the Front Panel
92
Verifying an LXI Trigger Using LXI Interactive
92
Configuring an LXI State Trigger
93
Using the LXI Event Log
94
Setting up and Executing a List Sweep Measurement
95
Synchronizing a List Sweep Measurement between an MXA and an MXG
96
For more Information
104
4 Programming Examples
107
X-Series Spectrum Analyzer Mode Programing Examples
108
89601X VXA Signal Analyzer Programming Examples
110
5 Installing Application Software
113
Installing Application Software
114
Viewing a License Key
114
Obtaining and Installing a License Key
114
Missing and Old Measurement Application Software
115
Agilent Technologies MXA N9020A Installation Note (14 pages)
MXA Signal Analyzer Front Frame Assembly Replacement
Brand:
Agilent Technologies
| Category:
Measuring Instruments
| Size: 0.67 MB
Advertisement
Agilent Technologies MXA N9020A Installation Note (10 pages)
Signal Analyzer. Option MS1, Upgrade to 2 GB SDRAM
Brand:
Agilent Technologies
| Category:
Measuring Instruments
| Size: 2.2 MB
Advertisement
Related Products
Agilent Technologies MXA Series
Agilent Technologies FieldFox MW N9913A
Agilent Technologies FieldFox MW N9914A
Agilent Technologies FieldFox MW N9918A
Agilent Technologies FieldFox MW N9917A
Agilent Technologies FieldFox MW N9916A
Agilent Technologies M90XA
Agilent Technologies M9391A
Agilent Technologies M9393A
Agilent Technologies M9302A
Agilent Technologies Categories
Measuring Instruments
Laboratory Equipment
Test Equipment
Water Pump
Power Supply
More Agilent Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL