EPSON AcuLaser C1100

4.5.5 CAM ASSY-2ND

REMOVAL
1.
Remove COVER ASSY RH.
(p.301)
2.
Remove CHUTE ASSY-FSR and COVER ASSY-RR 2ND.
3.
Remove 2ND BTR ASSY.
(p.348)
When performing the following work, there is no need to remove
C A U T I O N
WIRE ASSY 2BTR from PLATE BIAS-2ND ASSY.
4.
Remove PLATE BIAS-2ND ASSY.
When performing the following work, there is no need to remove
C A U T I O N
SENSOR 2BTR RETRACT from BRACKET-SENSOR PHOTO.
5.
Remove SENSOR 2BTR RETRACT.
When performing the following work, take care not to drop or lose
C A U T I O N
BEARING.
6.
Remove the E-ring fastening the right-side shaft on CAM ASSY-2ND to the main
unit, and slide BEARING to the left.
When performing the following work, work can be performed more
C H E C K
P O I N T
easily by pressing FRAME ASSY-2ND in the direction of the arrow,
and releasing FRAME ASSY-2ND from the cam on CAM ASSY-
2ND.
7.
Temporarily slide CAM ASSY-2ND to the right, and draw out the shaft on CAM
ASSY-2ND from the left-side bearing on the main unit, and remove CAM ASSY-
2ND together with BEARING.
8.
Remove BEARING from CAM ASSY-2ND.
DISASSEMBLY AND ASSEMBLY
(p.341)
(p.358)
(p.356)
6)-2
6)-1
8)
7)-2
CAUTION
RIGHT
Figure 4-64. Removal of CAM ASSY-2ND
TRANSFER
7)-1
7)-1
CAUTION
CAUTION
8)
CAUTION