3.11 Adjustment of Developer Unit

3.11.1
Doctor-to-sleeve gap
Adjustment tool to use: Doctor-sleeve jig
<Procedure>
(1)
Perform the adjustment code "05-280".
(2)
Take out the process unit from the equipment.
(3)
Take out the developer unit from the process unit.
(4)
Remove 2 screws and take off the developer
material cover and discharge the developer
material.
Note:
Discharge the developer material from the
rear side, being careful not to let it be
scattered on the gear.
(5)
Turn the adjustment screw to widen the gap
so that the jig can be inserted in it.
(Turning the screw clockwise widens the
gap)
e-STUDIO205L/255/305/355/455
ADJUSTMENT
© 2009 TOSHIBA TEC CORPORATION All rights reserved
3 - 58
Developer
material cover
Fig. 3-49
Screw
Fig. 3-50