To remove an MPC with an adapter card (ADC):
Have ready an antistatic mat for the MPC with an ADC. Also have ready rubber safety
1.
caps for each MPC using an optical interface on the MPC that you are removing.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
2.
the strap to an approved site ESD grounding point. See the instructions for your site.
Open both the ejector handles simultaneously to unseat the both the MPC and the
3.
ADC.
Grasp the handles, and slide the MPC along with the ADC straight out of the card cage
4.
halfway.
Place one hand around the front of the MPC with the ADC and the other hand under
5.
MPC to support it. Slide the MPC along with the ADC completely out of the chassis,
and place it on the antistatic mat or in the electrostatic bag.
CAUTION:
The weight of the MPC with the ADC is concentrated in the
back end. Be prepared to accept the full weight—up to
25.0 lb (11.34 kg)—as you slide the MPC along with the ADC out of the
chassis.
When the MPC along with the ADC is out of the chassis, do not hold it by
the ejector handles, bus bars, or edge connectors. They cannot support
its weight.
Do not stack MPCs with the ADCs on top of one another after removal.
Place each one individually in an electrostatic bag or on its own antistatic
mat on a flat, stable surface.
To remove an MPC without an ADC (see
Have ready an antistatic mat for the MPC. Also have ready rubber safety caps for each
1.
MPC that uses an optical interface on the MPC that you are removing.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
2.
the strap to an approved site ESD grounding point. See the instructions for your site.
Simultaneously turn both the knobs counterclockwise to unseat the MPC from the
3.
ADC.
Grasp both knobs, and slide the MPC straight out of the ADC.
4.
Place one hand around the front of the MPC and the other hand under it to support
5.
it. Slide the MPC completely out of the ADC, and place it on the antistatic mat or in
the electrostatic bag.