Mx2020 Three-Phase Delta And Wye Ac Power Distribution Module Leds; Figure 44: Dc Power Distribution Module - Juniper MX2020 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX2020:
Table of Contents

Advertisement

Related
Documentation

MX2020 Three-Phase Delta and Wye AC Power Distribution Module LEDs

Copyright © 2015, Juniper Networks, Inc.

Figure 44: DC Power Distribution Module

NOTE:
The type of feed that you use on the DC PDM (60 A or 80 A) depends
on the distribution scheme and distribution equipment. With a 60-A feed,
the maximum power supply output power is limited to 2100 W while the
maximum power supply input power is limited to 2400 W. With an 80-A feed,
the maximum power supply output is limited to 2500 W while maximum
power supply input power is limited to 2800 W. The system power
management software calculates the available and used power based on
DIP switch positions in the PDM.
MX2010 DC Power Distribution Module LEDs
MX2010 Router Grounding Specifications
Calculating DC Power Requirements for MX2010 Routers
DC Power Circuit Breaker Requirements for the MX2010 Router
MX2010 DC Power Distribution Description
DC Power Cable Specifications for the MX2010 Router
Site Electrical Wiring Guidelines for MX Series Routers on page 592
Figure 45 on page 92
shows the LEDs on the three-phase delta AC PDM faceplate. The
three-phase wye AC PDM has the same LEDs. The LEDs in
the status of the AC PDM. In addition, a PDM failure triggers the red alarm LED on the
craft interface.
Chapter 9: Power Subsystem
Table 31 on page 92
indicate