Mx2020 Router Grounding Specifications; Mx2020 Chassis Grounding Points Specifications; Mx2020 Router Grounding Cable Lug Specifications; Figure 69: Connecting Chassis Grounding Points On The Mx2020 Router - Juniper MX2020 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX2020:
Table of Contents

Advertisement

MX2020 Router Grounding Specifications

MX2020 Chassis Grounding Points Specifications

MX2020 Router Grounding Cable Lug Specifications

Copyright © 2015, Juniper Networks, Inc.
MX2020 Chassis Grounding Points Specifications on page 161
MX2020 Router Grounding Cable Lug Specifications on page 161
MX2020 Router Grounding Cable Specifications on page 162
To meet safety and electromagnetic interference (EMI) requirements and to ensure
proper operation, the router must be adequately grounded before power is connected.
To ground AC-powered or DC-powered routers, you must connect a grounding cable to
earth ground and then attach it to the chassis grounding points using the two screws
provided. (see
Figure 56 on page

Figure 69: Connecting Chassis Grounding Points on the MX2020 Router

CAUTION:
Before router installation begins, a licensed electrician must attach
a cable lug to the grounding and power cables that you supply. A cable with
an incorrectly attached lug can damage the router.
To ground AC-powered or DC-powered routers, connect a grounding cable to earth
ground and then attach it to the chassis grounding points using two screws. The top pair
of grounding points fits UNC 1/4–20 screws (American), and the lower pair fits M6 screws
(European). The grounding points are spaced at 0.625-in. (15.86-mm) centers. The cable
lugs get attached to the grounding cable, and the two UNC 1/4–20 screws are used to
secure the grounding cable to the top pair of grounding points.
WARNING:
The router is a pluggable type A equipment installed in a restricted
access location. It has a separate protective earthing terminal (Metric [–M6]
and English [–¼-20] screw ground lugs) provided on the chassis in addition
to the grounding pin of the power supply cord. This separate protective earth
terminal must be permanently connected to earth.
Chapter 13: AC Power Requirements, Specifications, and Guidelines
118).
161

Advertisement

Table of Contents
loading