Troubleshooting the MX2020 Host Subsystems

Problem
536
Table 100: MX2020 Cooling System Alarms (continued)
Alarm
Component
Type
Temperature
Red
sensors
Yellow
MX2020 Craft Interface Description on page 37
Replacing an MX2020 Fan Tray on page 471
Maintaining the MX2020 Air Filter on page 341
Maintaining the MX2020 Fan Trays on page 345
Description: The following alarms and LEDs indicate a problem with a host subsystem
Control Board and Routing Engine (CB-RE):
A red alarm indicates that the host subsystem has been removed.
The red host subsystem
CLI Message
Alarm Condition
Temperature Hot
The chassis
temperature
exceeded the hot
temperature
threshold. If this
condition persists,
the router shuts
down.
Temperature sensor
A temperature
sensor failed.
failure
Temperature Warm
The chassis
temperature
exceeded the
warm
temperature
threshold.
LED on the craft interface is lit.
OFFLINE
Solution
Verify that the
room
temperature is
within
acceptable
limits.
Verify that
there is
sufficient air
flow.
Verify that the
cooling system
in the chassis
is operating
properly.
Contact JTAC
Verify that the
room
temperature is
within
acceptable
limits.
Verify that
there is
sufficient air
flow.
Verify that the
cooling system
in the chassis
is operating
properly.
Copyright © 2015, Juniper Networks, Inc.