 Digital Input Settings
The MC Function Module uses the following input signals of the Servo Drive.
Function name
Positive limit switch
(positive drive prohibit
input)
Negative limit switch
(negative drive prohibit
input)
Immediate stop input
Encoder Phase Z
Detection (encoder Z-
phase detection)
Home switch (home
proximity input)
External Latch Input 1
External Latch Input 2
Precautions for Correct Use
Precautions for Correct Use
• Some functions may not be supported if you a connect unit versions of the G5-series Servo
Drives with built-in EtherCAT communications other than the recommended unit versions.
Refer to the manual for the connected servo drive for details.
• If you change the settings, make sure that the desired operations are performed for the MC
Function Module and process data settings.
NY-series Industrial Panel PC / Industrial Box PC Motion Control User's Manual (W559)
Process data
60FD hex-00.1 (Digital
inputs)
60FD hex-00.0 (Digital
inputs)
60FD hex-00.25 (Digital
inputs)
60FD hex-00.16 (Digital
inputs)
60FD hex-00.2 (Digital
inputs)
60FD hex-00.17 (Digital
inputs)
60FD hex-00.18 (Digital
inputs)
Description
This signal is used for the positive limit input.
Normally set Bit 1: Positive limit switch of 60FD
hex-00: Digital inputs.
This signal is used for the negative limit input.
Normally set Bit 0: Negative limit switch of 60FD
hex-00: Digital inputs.
This signal is used for the immediate stop input.
Set Bit 25: Immediate Stop Input of 60FD hex-00:
Digital inputs for an OMRON G5-series Servo
Drive.
Shows the status of detecting the Z-phase input.
For OMRON G5-series Cylinder-type Servomo-
tors/Servo Drives with unit version 2.1 or later, set
bit 16 (Encoder Phase Z Detection) of 60FD hex-
00 (Digital Inputs).
G5-series Linear Motor Type Servo Drives do not
support this object.
This signal is used for the home proximity input.
Normally set Bit 2: Home switch of 60FD hex-00:
Digital inputs.
Shows the status of the signal that is used for
external latch input 1.
Set Bit 17: External Latch Input 1 of 60FD hex-00:
Digital inputs for an OMRON G5-series Servo
Drive.
Shows the status of the signal that is used for
external latch input 2.
Set Bit 18: External Latch Input 2 of 60FD hex-00:
Digital inputs for an OMRON G5-series Servo
Drive.
Appendices
A
A-19