Omron NY532-1500 User Manual page 204

Ny-series ipc machine controller industrial panel pc / industrial box pc
Hide thumbs Also See for NY532-1500:
Table of Contents

Advertisement

9 Motion Control Functions
• Immediate Stop and Error Reset
Velocity
• Immediate Stop and Servo OFF
Velocity
Stop Priorities
The priorities for each stop method are listed in the following table. If a stop with a higher priority stop
method occurs while stopping, the stop method will switch to the higher priority method.
Immediate stop and Servo OFF
Immediate stop and error reset
Immediate stop
Deceleration stop
Example:
The following figure is an example of an immediate stop when the limit input signal is ON and the
immediate stop input changes to ON during a deceleration to a stop.
Limit input
Immediate stop input
Command velocity
9-10
The actual position when the cause of the
immediate stop occurred is used as the
command position. Inertia will take the axis
past this position, but it will return to the
actual position when the cause of the
immediate stop occurred and stop there.
Time
The command is no longer updated. When
the Servo is turned OFF, the axis stops using
the method that is specified by the Disable
Operation Option Code (object 605C hex)
that is set in the Servo Drive.
Time
Stop method