Acceleration And Deceleration - Omron NY532-1500 User Manual

Ny-series ipc machine controller industrial panel pc / industrial box pc
Hide thumbs Also See for NY532-1500:
Table of Contents

Advertisement

Monitoring Velocities
You can read Axis Variables in the user program to monitor velocities.
Variable name
_MC_AX[0-63].Cmd.Vel
_MC_AX[0-63].Act.Vel
9-5-3

Acceleration and Deceleration

Unit of Acceleration and Deceleration Rates
Acceleration rates and deceleration rates are given in command units/s
value obtained from unit conversion of the position display unit and the electronic gear.
Axis Parameters That Are Related to Acceleration and Deceleration
Parameter name
Maximum Acceleration
Maximum Deceleration
Acceleration/Decelera-
tion Over
Acceleration Warning
Value
Deceleration Warning
Value
NY-series Industrial Panel PC / Industrial Box PC Motion Control User's Manual (W559)
Data type
LREAL
Command Current
Velocity
LREAL
Actual Current
Velocity
Function
Set the maximum acceleration rate for an axis
operation command. There will be no limit to
the acceleration rate if 0 is set.
2
(Unit: command units/s
)
Set the maximum deceleration rate for an axis
operation command. There will be no limit to
the deceleration rate if 0 is set.
2
(Unit: command units/s
)
Set the operation for when the maximum accel-
eration/deceleration rate would be exceeded
after excessive acceleration/deceleration
during acceleration/deceleration control of the
axis because stopping at the target position is
given priority.
0: Use rapid acceleration/deceleration. (Blend-
ing is changed to Buffered.)
1: Use rapid acceleration/deceleration.
*2
2: Minor fault stop
Set the percentage of the maximum accelera-
tion rate at which to output an acceleration
warning for the axis. No acceleration warning is
output if 0 is set.
(Unit: %)
Set the percentage of the maximum decelera-
tion rate at which to output a deceleration warn-
ing for the axis. No deceleration warning is
output if 0 is set.
(Unit: %)
9 Motion Control Functions
Meaning
This is the current value of the command
velocity. A plus sign is added during
travel in the positive direction, and a
minus sign is added during travel in the
negative direction.
This is the actual current velocity. A plus
sign is added during travel in the positive
direction, and a minus sign is added
during travel in the negative direction.
2
. The command unit is the
Setting range
Non-negative long
reals
Non-negative long
reals
0 to 2
*1
0 to 100
0 to 100
Function
Default
0
0
0
0
0
9-33
9