Omron NYB17-*100 SERIES User Manual

Omron NYB17-*100 SERIES User Manual

Ipc without operating system ny-series
Table of Contents

Advertisement

Quick Links

Industrial PC Platform
NY-series
IPC Without Operating System
Industrial Box PC
User's Manual
NYB17-£100£
NYB25-£100£
NYB1C-£100£
Industrial Box PC
W586-E2-02

Advertisement

Table of Contents
loading

Summary of Contents for Omron NYB17-*100 SERIES

  • Page 1 Industrial PC Platform NY-series IPC Without Operating System Industrial Box PC User's Manual NYB17-£100£ NYB25-£100£ NYB1C-£100£ Industrial Box PC W586-E2-02...
  • Page 2 Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publica- tion.
  • Page 3: Intended Audience

    Introduction Introduction Thank you for purchasing the Box PC Without Operating System. This manual contains information that is necessary to use the Box PC Without Operating System (hereafter also named as Box PC). Please read this manual and make sure you understand the func- tionality and performance of the Box PC before attempting to use it.
  • Page 4: Table Of Contents

    CONTENTS CONTENTS Introduction ......................1 Intended Audience............................1 Applicable Products ............................1 Manual Information....................7 Page Structure..............................7 Special Information ............................8 Terms and Conditions Agreement................9 Warranty and Limitations of Liability ........................9 Application Considerations ..........................10 Disclaimers ..............................10 Safety Precautions....................12 Definition of Precautionary Information......................12 Symbols .................................12 Warnings................................13 Cautions.................................15...
  • Page 5 CONTENTS Section 1 Overview Intended Use ........................1 - 2 Hardware Features.......................1 - 3 ID Information Label ......................1 - 4 Product Configuration......................1 - 5 Industrial PC Platform Overview ..................1 - 6 1-5-1 Industrial Monitor ........................1 - 6 1-5-2 Industrial Box PC ........................1 - 7 1-5-3 Industrial Panel PC ........................1 - 7 Section 2...
  • Page 6 CONTENTS Support Software .........................3 - 3 3-2-1 Overview IPC Support Software for Windows................3 - 3 3-2-2 Overview IPC Developer Software for Windows ...............3 - 3 Section 4 Specifications General Specifications .......................4 - 2 4-1-1 Dimensions and Weight ......................4 - 2 4-1-2 General Electrical Specifications....................4 - 3 4-1-3...
  • Page 7 CONTENTS Install Software ........................5 - 48 5-7-1 Drivers and Custom Software ....................5 - 48 Connect UPS ........................5 - 49 5-8-1 Connect UPS Using the USB Connector ................5 - 50 5-8-2 Connect UPS Using the I/O Connector ...................5 - 52 Section 6 Operating Procedures Power ON..........................6 - 2 6-1-1...
  • Page 8 CONTENTS NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 9: Manual Information

    Manual Information Manual Information This section provides information about this manual. Page Structure The following page structure is used in this manual. 5 Installation Unpack This section provides details on how to unpack the Industrial Panel PC. 5-1-1 Unpack Procedure Check the package for damage.
  • Page 10: Special Information

    Manual Information Special Information Special information in this manual is classified as follows: Precautions for Safe Use Precautions on what to do and what not to do to ensure safe usage of the product. Precautions for Correct Use Precautions on what to do and what not to do to ensure proper operation and performance. Additional Information Additional information to read as required.
  • Page 11: Terms And Conditions Agreement

    Omron’s exclusive warranty is that the Products will be free from defects in materials and workman- ship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, expressed or implied.
  • Page 12: Application Considerations

    • Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. • Omron Companies shall not be responsible for the operation of the user accessible operating sys- tem (e.g. Windows, Linux), or any consequence thereof.
  • Page 13 Terms and Conditions Agreement Errors and Omissions Information presented by Omron Companies has been checked and is believed to be accurate; how- ever, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 14: Safety Precautions

    Safety Precautions Safety Precautions Definition of Precautionary Information The following notation is used in this manual to provide precautions required to ensure safe usage of the Box PC Without Operating System. The safety precautions that are provided are extremely impor- tant to safety.
  • Page 15: Warnings

    Safety Precautions Warnings WARNING Disassembly and Dropping Do not attempt to disassemble, repair, or modify the product in any way. Do- ing so may result in malfunction or fire. Installation Always connect to a ground of 100 Ω or less when installing the product. Ensure that installation and post-installation checks of the product are per- formed by personnel in charge who possess a thorough understanding of the machinery to be installed.
  • Page 16 Safety Precautions Actual Operation Security setting adjustments should only be performed by the engineer in charge that possesses a thorough understanding of the security settings. Selecting non-recommended security settings can put your system at risk. Changing BIOS information is only allowed for the engineer in charge that possesses a thorough understanding of the BIOS settings because it can change the behavior of the product.
  • Page 17: Cautions

    Safety Precautions Cautions Caution Wiring The product has an internal non-isolated DC power supply. Circuit ground (0 VDC) and frame ground are connected together. When connecting a non- isolated device or a non-isolated interface to the product, take appropriate actions to avoid communication failures or damage to the mentioned ports. Non-isolated Industrial PC Platform Product Device...
  • Page 18: Precautions For Safe Use

    Precautions for Safe Use Precautions for Safe Use Disassembly, Dropping, Mounting, Installation and Storage • Do not drop the product or subject it to abnormal vibration or shock. Doing so may result in product malfunction or burning. • When unpacking, check carefully for any external scratches or other damages. Also, shake the product gently and check for any abnormal sound.
  • Page 19: Actual Operation

    • Correctly perform wiring and setting, and ensure that the shutdown by the UPS can be executed. • Always use the SMART monitoring feature for storage devices that do not comply to the Omron Storage Device Specifications. Monitor the operating temperature and vibrations to ensure they stay within the environmental specifications of the storage device.
  • Page 20: General Communications

    Precautions for Safe Use • Do not touch any product housing when power is being supplied or immediately after the power sup- ply is turned OFF. Doing so may result in burn injury. General Communications • Separate the machine network segment from the office network to avoid communication failures. Battery Replacement •...
  • Page 21: Precautions For Correct Use

    OS boot failure or crash. • Ensure the selected operating system supports ACPI to enable operating system shutdown using the power button. • Download the enhanced Video Driver from the OMRON Download Center and install it on the Indus- trial PC. Wiring •...
  • Page 22: Actual Operation And Operation

    Precautions for Correct Use • Do not weld the conductors. Doing so may cause the wires to break with vibration. Actual Operation and Operation • After an OS update or a peripheral device driver update for the product is executed, the product be- havior might be different.
  • Page 23: Regulations And Standards

    EMC Directive EMC Directive OMRON devices that comply with EU Directives also conform to the related EMC standards so that they can be more easily built into other devices or the overall machine. The actual products have been checked for conformity to EMC standards.
  • Page 24: Conformance To Kc Standards

    Software Licenses and Copyrights This product incorporates certain third party software. The license and copyright information associat- ed with this software is available at http://www.fa.omron.co.jp/nj_info_e/. NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 25: Related Manuals

    Related Manuals Related Manuals The following manuals are related. Use these manuals for reference. Related Products Manuals Manual Cat. Model num- Application Description name bers U702 S8BA Learning the information An introduction to the UPS is provided S8BA User's that is necessary to use along with the following information: •...
  • Page 26: Industrial Monitor Manual

    Related Manuals Industrial Monitor Manual This table contains the related manual of the Industrial Monitor. Cat. Manual name Model numbers Application Description Industrial Monitor Us- W554 NYM15W-C100£ Learning all basic infor- An introduction to the er’s Manual NYM15W-C106£ mation about the Indus- Industrial Monitor is NYM12W-C100£...
  • Page 27: Terminology And Abbreviations

    Term / Abbreviation Description Industrial PC Platform An integrated range of OMRON products designed for use in any industrial applica- tion that will benefit from advanced PC technology Industrial Monitor An industrial monitor with a touchscreen as the user interface designed to work in...
  • Page 28: Software

    Terminology and Abbreviations Software Term / Abbreviation Description ACPI Advanced Configuration and Power Interface protocol for operating systems Application Programming Interface BIOS Basic Input Output System. The first software run by a PC when powered on. Developer Any person involved with the development of software Daylight Saving Time Enhanced Write Filter FBWF...
  • Page 29: Revision History

    Revision History Revision History A manual revision code appears as a suffix to the catalog number on the front and back covers of the manual. W586-E2-02 Cat. No. Revision code Revision code Date Revised content June 2017 Added NY Monitor Link option April 2017 First release NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 30 Revision History NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 31: Sections In This Manual

    Sections in this Manual Sections in this Manual Overview Hardware Software Specifications Installation Operating Procedures Maintenance Appendices NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 32 Sections in this Manual NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 33 Overview This section provides general information about the Box PC Without Operating Sys- tem. Intended Use ....................1 - 2 Hardware Features ..................1 - 3 ID Information Label..................1 - 4 Product Configuration ................. 1 - 5 Industrial PC Platform Overview ..............1 - 6 1-5-1 Industrial Monitor ..................
  • Page 34: Overview

    1 Overview Intended Use The Box PC Without Operating System (also indicated as Box PC) is an industrial-grade PC intended for use within factory automation environments. This Box PC can be configured with Windows, Linux or a realtime operating system (RTOS). It can be used with third party software to serve as a powerful PC platform.
  • Page 35: Hardware Features

    An extra (optional) DVI interface is available for connection to a second monitor. • NY Monitor Link interface The interface combines video signals and USB signals for a connection to an OMRON Industrial Monitor using a single NY Monitor Link cable up to 100 meter.
  • Page 36: Id Information Label

    A custom ID [NYC£££-££££££££] (Optional) Only for Industrial Monitors and Industrial Panel PCs with a custom logo Standards and QR The applicable standards and a QR code for OMRON internal use code LOT number and Production details, consisting of: •...
  • Page 37: Product Configuration

    1 Overview Product Configuration This section provides an overview of the product configurations available for the Box PC Without Op- erating System. The product configuration is visible in the model-type that is mentioned on the ID information label of the product. The structure of the model-type is: NYB££-£££££.
  • Page 38: Industrial Pc Platform Overview

    In line with OMRON’s established quality standards, each element in the Industrial PC Platform, rang- ing from the standalone Industrial Box PC to the touchscreen Industrial Monitor, is engineered with long-life components and built to the most advanced design standards.
  • Page 39: Industrial Box Pc

    1 Overview 1-5-2 Industrial Box PC The Industrial Box PC is designed to meet the specific needs of the industrial environment. Design simplification and future-proof architecture minimize the risk of failure. In addition, new PC features can be seamlessly incorporated, without the need for wholesale redesign. 1-5-3 Industrial Panel PC The Industrial Panel PC intelligently combines the functionality of the Industrial Box PC and Industrial...
  • Page 40 1 Overview 1 - 8 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 41 Hardware This section provides an overview of the hardware of the Box PC Without Operating System. Component Names and Functions ............. 2 - 3 2-1-1 Front and Top of the Industrial Box PC............2 - 3 2-1-2 Back of the Industrial Box PC ............... 2 - 5 LED Indicators ....................
  • Page 42 2 Hardware 2-9-9 Power Supply....................2 - 23 2-9-10 UPS ......................2 - 24 2-9-11 UPS Communication Cable ................ 2 - 24 2 - 2 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 43: Component Names And Functions

    2 Hardware Component Names and Functions This section shows views of the Box PC Without Operating System with information about all items. 2-1-1 Front and Top of the Industrial Box PC This section shows the component names and functions for the front and top of the Box PC. Item Name Description...
  • Page 44 2 Hardware Item Name Description Option port Interface connection options for peripheral devices or an additional monitor: • RS-232C connector • DVI-D connector • NYML connector SD Memory Card slot SD Memory Card slot PCIe bay PCI Express mounting slot DVI connector Digital Visual Interface connector 10BASE-T/100BASE-...
  • Page 45: Back Of The Industrial Box Pc

    2 Hardware 2-1-2 Back of the Industrial Box PC This section shows the component names and functions for the back of the Industrial Box PC. Item Name Description ID information label Label containing Model ID., LOT No. and other product specific information. License label Optional label containing the license number.
  • Page 46: Led Indicators

    2 Hardware LED Indicators The Industrial Box PC has two rows of four LED indicators that show the operating status of the prod- uct. Both rows have the same function. The following LED indicators are available: Item Name Description Indicator Power Indicates the operating mode of the Industrial Box PC.
  • Page 47: Err Led Indicator

    2 Hardware 2-2-2 ERR LED Indicator The Error LED (ERR) indicates the presence and type of an error within the Box PC. Color Status Meaning • Not lit The 24 VDC power is not supplied • No error is present •...
  • Page 48: Power Button

    2 Hardware Power Button The power button is used to manually switch the Box PC ON and OFF. Additional Information • Refer to 6-1 Power ON on page 6 - 2 for ON details. • Refer to 6-2 Power OFF on page 6 - 3 for OFF details. 2 - 8 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 49: Drive Bays

    2 Hardware Drive Bays The drive bays in the Box PC Without Operating System accept 2.5 inch Hard Disk Drives (HDD) or Solid State Drives (SSD). Depending on the model one or two drives are supported. Additional Information • Refer to 4-1-4 CPU Specifications on page 4 - 6 for the number of supported drives. •...
  • Page 50: Sd Memory Card Slot

    2 Hardware SD Memory Card Slot The SD Memory Card slot on the Box PC Without Operating System accepts SD Memory Cards with the following specifications. • SDHC type (SD 2.0 specification) • Up to 32 GB capacity Additional Information Refer to 2-9-2 SD Memory Cards on page 2 - 19 for SD Memory Card details.
  • Page 51: Pcie Card Slot

    2 Hardware PCIe Card Slot The PCI Express (PCIe) Card slot of the Box PC Without Operating System accepts various PCIe Cards for specific hardware needs. The PCIe Card connectors are available behind the cover and the PCIe Card is mounted in the PCIe drawer Additional Information •...
  • Page 52: Connectors

    2 Hardware Connectors This section gives an overview of the available connectors for the Box PC Without Operating System. 2-7-1 Power Connector The power connector on the Box PC is used to supply 24 VDC power to the Box PC. The power connector is supplied with the Box PC.
  • Page 53: Usb Connectors

    2 Hardware Additional Information • Refer to 4-2-2 I/O Connector Specifications on page 4 - 14 for specifications. • Refer to 5-4-4 Wire the I/O Connector on page 5 - 39 for wiring details. • Refer to 5-5 Connect on page 5 - 42 for connection details. 2-7-3 USB Connectors The USB connectors support USB 2.0 and USB 3.0 specifications.
  • Page 54: Ethernet Connectors

    2 Hardware 2-7-4 Ethernet Connectors The Ethernet connectors provide 3 individual Ethernet ports on the Box PC Without Operating System. Each port offers 10BASE-T/100BASE-TX/1000BASE-T Ethernet speeds. Additional Information • Refer to 4-2-4 Ethernet Connector Specifications on page 4 - 19 for specifications. •...
  • Page 55: Rs-232C Connector (Optional)

    2 Hardware 2-7-6 RS-232C Connector (Optional) Depending on the product configuration an optional RS-232C connector is available. Additional Information • Refer to 1-4 Product Configuration on page 1 - 5 for configuration details. • Refer to 4-2-7 RS-232C Connector Specifications on page 4 - 23 for specifications. •...
  • Page 56: Ny Monitor Link Connector (Optional)

    2 Hardware 2-7-8 NY Monitor Link Connector (Optional) Depending on the product configuration this NY Monitor Link connector is available. The NY Monitor Link interface connector connects an OMRON Industrial PC to the OMRON Industrial Monitor. Industrial PC Industrial Monitor Additional Information •...
  • Page 57: Spare Parts

    2 Hardware Spare Parts The following spare parts for the Box PC Without Operating System are available. 2-8-1 Battery One battery is supplied with the Box PC. The battery supplies power to the real-time clock. The battery is located inside the Box PC. Model Appearance Specifications...
  • Page 58: Accessory Kit

    2 Hardware 2-8-3 Accessory Kit The accessory kit for the Box PC. Model Appearance Specifications NY000-AK00 Accessory Kit containing all accessories sup- plied with the Box PC. • Power connector • I/O connector • Drive bracket for drive installation • 4 mounting screws for drive installation •...
  • Page 59: Optional Hardware

    Book mount NY000-AB01 Wall mount 2-9-2 SD Memory Cards SD Memory Card details are provided below. OMRON is not responsible for the operation, performance or write life of any other brand of SD Memo- ry Card. Model Appearance Card type Capacity...
  • Page 60: Usb Flash Drives

    2 Hardware 2-9-3 USB Flash Drives USB Flash Drive details are provided below. OMRON is not responsible for the operation, performance, or write life of any other brand of USB Flash Drives. Model Appearance Capacity FZ-MEM2G 2 GB FZ-MEM8G 8 GB...
  • Page 61: Dvi Cables

    90 mm 2-9-6 USB Type-A to USB Type-B Cables USB Type-A to USB Type-B cable details are provided below. OMRON is not responsible for the operation or performance of any other brand of USB Type-A to USB Type-B cable. Model Appearance...
  • Page 62: Ny Monitor Link Cables

    2 Hardware 2-9-7 NY Monitor Link Cables The following table lists the recommended cables and connectors for the NY Monitor Link cable. Intra cabinet or Inter cabinet and Application light industrial en- Inter cabinet harsh industrial vironment environment Maximum length 25 m 100 m 100 m...
  • Page 63: Industrial Monitor

    Additional Information Refer to the OMRON website for specifications and manuals. 2-9-9 Power Supply Details for the recommended power supply are provided below. OMRON is not responsible for the operation or performance of any other power supply. Model Appearance Specifications S8VK-G£££24...
  • Page 64: Ups

    • Refer to 4-1-3 Power Consumption Specifications on page 4 - 4 for power consumption de- tails. • Refer to the OMRON website for S8BA specifications or to the UPS S8BA User's Manual (Cat. No. U702) for the UPS manual.
  • Page 65: Software

    Software This section provides software information for the Box PC Without Operating System. Compatible Operating Systems ..............3 - 2 Support Software ..................3 - 3 3-2-1 Overview IPC Support Software for Windows ..........3 - 3 3-2-2 Overview IPC Developer Software for Windows .......... 3 - 3 3 - 1 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 66: Compatible Operating Systems

    3 Software Compatible Operating Systems The operating system installed on the Box PC must be: • compatible with the Advanced Configuration and Power Interface (ACPI) protocol • installed on the storage device in drive bay A Compatible operating systems for the Box PC are: •...
  • Page 67: Support Software

    Industrial Monitor Brightness Utility Industrial PC Support Utility Industrial PC Tray Utility Select and download the utilities required from the OMRON download website. Additional Information • An internet connection is required to install support software. • Refer to NY-series Industrial Panel PC User’s Manual (Cat. No. W555) for support software details.
  • Page 68 3 Software 3 - 4 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 69: Specifications

    Specifications This section provides specifications of the Box PC Without Operating System. General Specifications ................4 - 2 4-1-1 Dimensions and Weight ................4 - 2 4-1-2 General Electrical Specifications ..............4 - 3 4-1-3 Power Consumption Specifications .............. 4 - 4 4-1-4 CPU Specifications ..................
  • Page 70: General Specifications

    4 Specifications General Specifications This section provides general specifications of the Box PC Without Operating System. 4-1-1 Dimensions and Weight The following table provides specification details on dimensions and weights. Specifications with book Specifications with wall Item Specifications mount bracket mount brackets Dimensions Width X = 282 mm...
  • Page 71: General Electrical Specifications

    4 Specifications 4-1-2 General Electrical Specifications The following table provides the general electrical specifications. Item Specifications Rated power supply voltage 24 VDC Allowable power supply voltage range 20.4 to 28.8 VDC Power supply standard SELV Grounding method Ground to less than 100 Ω Inrush current At 24 VDC: 12 A / 6 ms max.
  • Page 72: Power Consumption Specifications

    4 Specifications 4-1-3 Power Consumption Specifications The following tables provide details on the power consumption of the Box PC Without Operating Sys- tem. The total power consumption is the sum of the power consumption of all items that are installed in your Box PC.
  • Page 73 4 Specifications Item Power consumption HDD 320 GB Drives SSD SLC 32 GB SSD SLC 64 GB SSD iMLC 128 GB 14 W max. ((2 x 500 mA at 5 V) + (2 x 900 mA at 5 V)) Expansions PCIe 5 W max.
  • Page 74: Cpu Specifications

    4 Specifications 4-1-4 CPU Specifications This section gives the specifications of the CPUs that are available for the Box PC Without Operating System. Refer to 1-4 Product Configuration on page 1 - 5 for product configuration details. ® ™ Intel Core i7-4700EQ CPU Specifications ®...
  • Page 75: Memory Specifications

    4 Specifications Item Specifications Maximum turbo frequency Cache 2 MB Cooling details Passive cooling (fanless) Drive bays (HDD/SSD) 1. Drive bay A. Graphics controller Intel ® HD Graphics. Up to two independent screens. 4-1-5 Memory Specifications The following table provides specification details of the memory. Model Specifications Item 2 GB...
  • Page 76: Storage Device Specifications

    4 Specifications 4-1-6 Storage Device Specifications This section provides the specifications of the storage devices. Hard Disk Drive Specifications Specifications for the Hard Disk Drive (HDD) are provided in the table below. Model Specifications Item 320 GB Model NY000-AH00 S.M.A.R.T. support Rotation speed 5,400 r/min Interface...
  • Page 77 4 Specifications Model Specifications Item 32 GB 64 GB 128 GB Life 1500 TB/11 years at a 3000 TB/23 years at a 114 TB/3 years at a daily daily workload of 350 GB daily workload of 350 GB workload of 100 GB Refer to 1-4 Product Configuration on page 1 - 5 for product configuration details.
  • Page 78: Pcie Card Specifications

    4 Specifications 4-1-7 PCIe Card Specifications The PCI Express (PCIe) Card slot of the Box PC Without Operating System accepts various cards for specific hardware needs. Ensure that, according to the PCIe hardware specifications, the indent is present in the PCIe Card. The following tables provide PCIe Card details per CPU type.
  • Page 79 4 Specifications ® ® PCIe Card Slot Specifications with an Intel Celeron 2980U CPU ® The table below provides PCIe Card slot details for Box PC Without Operating Systems with an Intel ® Celeron 2980U CPU. Item Specifications Configuration X1 (1 lane) up to Gen 2 Card height Standard height cards, 4.20 inches (106.7 mm) Card length...
  • Page 80: Bracket Specifications

    4 Specifications 4-1-8 Bracket Specifications The metal mounting brackets mount your Box PC and they are the connection for the functional ground. Use metal screws with a diameter of 4 mm or 5 mm to mount the brackets. Mounting screw locations for book mount and wall mount orientation: Additional Information •...
  • Page 81: Connector Specifications

    4 Specifications Connector Specifications This section provides the Connector Specifications of the Box PC Without Operating System. 4-2-1 Power Connector Specifications The power supply connector can be locked to prevent unintentional disconnection. The connector can only be inserted the correct way. The connector is a Phoenix Contact type SPC5/2-STCL-7.62 BK (1711708).
  • Page 82: I/O Connector Specifications

    4 Specifications Locking and Removing the Power Connector The power connector automatically locks into place when the black part of the connector is held and pushed in. Pushing both orange sliders towards the end of the connector will release the lock when remov- ing the connector.
  • Page 83 4 Specifications I/O Connector Pin Details The pin details of the I/O connector. The pin layout represents the I/O connector on the Box PC. The I/O signals connected must be powered from a power supply which conforms to the SELV stand- ards.
  • Page 84 4 Specifications I/O Connector Power Status Output Details This section provides details of the Power Status Output relay. The Power Status Output is a relay between pin 1 and 2 of the I/O Connector.  Power ON Power Status Output Operation This section provides power ON details of the Power Status Output operation.
  • Page 85 4 Specifications Product ON Shutdown Shutdown Product OFF start finished Closed (ON) Relay Open (OFF) Power supply removed Closed (ON) Relay Open (OFF) Additional Information Refer to 5-4-4 Wire the I/O Connector on page 5 - 39 for I/O connector wiring details. Lock and Remove the I/O Connector The I/O connector locks into place when the black part of the connector is held and pushed in.
  • Page 86: Usb Connector Specifications

    4 Specifications 4-2-3 USB Connector Specifications The Box PC Without Operating System includes four USB connectors. Two connectors provide ver- sion 2.0 performance and two connectors provide version 3.0 performance. Details of the USB inter- face connectors are provided below. The connector layout represents the USB connectors on the Box PC.
  • Page 87 4 Specifications 4-2-4 Ethernet Connector Specifications Details of the RJ45 Ethernet connectors are provided below. The Ethernet connector locks automatically to prevent unintentional disconnection. The view represents the Ethernet connector on the Box PC Without Operating System. Ethernet Connector LED Indicators Each connector has LED indicators for speed, link and activity.
  • Page 88: Ethernet Connector Specifications

    4 Specifications Item Indicator Color Status Description Speed Not lit Not lit 10 Mbps or no link Green 100 Mbps link Orange 1 Gbps link Ethernet Connector Specifications Item Specifications Number of available ports Physical layer 10BASE-T, 100BASE-TX or 1000BASE-T Frame length 1,514 bytes max.
  • Page 89: Dvi Connector Specifications

    4 Specifications 4-2-5 DVI Connector Specifications DVI is the standard video interface for the Box PC. The video interface depends on the model of the Box PC as specified below: Additional Information • Refer to 4-1-4 CPU Specifications on page 4 - 6 for graphics controller details. •...
  • Page 90: Dvi-D Connector Specifications

    4 Specifications ® ® DVI-D Connector Specifications with an Intel Celeron 2980U CPU ® ® DVI-D connector specifications for Box PC Without Operating System with an Intel Celeron 2980U CPU. Item Specifications Video interface Digital only Resolution Up to 1920 x 1200 pixels at 60 Hz Type Dual link Maximum DVI cable length...
  • Page 91: Rs-232C Connector Specifications

    4-2-8 NY Monitor Link Connector Specifications The NY Monitor Link connector connects an OMRON Industrial Monitor with an OMRON Industrial PC that has an NY monitor link connector. The NY Monitor Link communication is a combination of video and USB information.
  • Page 92 4 Specifications Industrial PC Industrial Monitor NY Monitor Link Connector LED Indicators The connector has LED indicators Connected and Video NYML Indica- Item Color Status Description Con- Yellow Not lit Not connected nected Connected USB communication active Video Green Not lit No video signal Blinking Video signal present...
  • Page 93: Environmental Specifications

    4 Specifications Environmental Specifications This section provides environmental specifications of the Box PC Without Operating System. 4-3-1 Operation Environment Specifications The following table provides the general environmental specifications for the Industrial Box PC. Item Specifications Ambient operating temperature 0 to 55°C Ambient storage temperature -20 to 70°C Ambient operating humidity...
  • Page 94: Temperature And Humidity Specifications

    4 Specifications 4-3-2 Temperature and Humidity Specifications The allowed ambient operating temperature and ambient humidity depend on product type, CPU type, mounting orientation, and storage device type. The following sections provide temperature and humidity details per CPU type. Temperature and Humidity Graphs The maximum ambient operating temperature and ambient humidity are specified per CPU type, mounting orientation and storage device type.
  • Page 95 4 Specifications • Store the Box PC with a SSD within the general environmental specifications. • Store the Box PC with a HDD within the ambient temperature and humidity ranges as shown in fol- lowing graph. Storage temperature- Storage humidity range temperature-humidity range Temperature [°C]...
  • Page 96: Recycling Specifications

    4 Specifications ® ® Temperature Specifications with an Intel Celeron 2980U CPU ® ® Ambient operating temperature specifications for a Box PC with an Intel Celeron 2980U CPU. Storage device type Mounting Orientation Book 0 to 55°C 5 to 45°C Wall 0 to 50°C 5 to 40°C...
  • Page 97: Installation

    Installation This section provides all installation details for the Box PC Without Operating System. Unpack ......................5 - 2 5-1-1 Unpack Procedure ..................5 - 2 5-1-2 Items Supplied ....................5 - 2 Install Options ....................5 - 5 5-2-1 Install a Drive ....................
  • Page 98: Unpack

    5 Installation Unpack This section provides details on how to unpack the Box PC Without Operating System. 5-1-1 Unpack Procedure Check the package for damage. If there is any visible damage: • Take photos of the package and save them. •...
  • Page 99 5 Installation Items Supplied with the Industrial Box PC This section describes the items supplied with your Industrial Box PC. • Industrial Box PC • Documentation: • Safety Precautions sheets (English and Japanese) • EU Compliance sheet • Standards and Certifications sheet •...
  • Page 100 5 Installation Items Supplied with the Brackets This section describes the items supplied with the brackets for your Industrial Box PC. Additional Information • Refer to 2-9-1 Mounting Brackets on page 2 - 19 for bracket details. • Refer to 5-3-8 Book Mount Procedure on page 5 - 26 for book mount installation. •...
  • Page 101: Install Options

    5 Installation Install Options This section describes the installable options for the Box PC Without Operating System. 5-2-1 Install a Drive A drive is a storage device for the Box PC Without Operating System. Additional Information • Depending on the product configuration a drive is already installed. Refer to 1-4 Product Configuration on page 1 - 5 for storage details.
  • Page 102 5 Installation Pull the metal shielding cover out of the Box PC. Align the connectors of the drive as shown on the bracket. Then insert the replacement drive in the bracket and insert the 4 mounting screws . Tighten these screws with a tor- que of 0.35 N·m.
  • Page 103 5 Installation Insert the bracket with the drive in the correct bay. • A drive for the operating system has to be inserted in bay A • The drive for additional storage can be inserted in bay B Ensure the bracket is completely in the Box PC with an extra push. The drive bracket will lock into place when it is fully inserted.
  • Page 104 5 Installation Mount the drive cover. The lock lever will click when closed correctly. Finalize the drive installation when the Box PC installation is completed. • If the drive is inserted in bay A: (1) Install an operating system (2) Power OFF and then Power ON (3) Ensure the drive is functional and confirm normal operation.
  • Page 105: Install The Pcie Card

    5 Installation 5-2-2 Install the PCIe Card Prepare the following items: • The PCIe Card. A PCIe Card is not supplied with the Box PC. Additional Information Refer to 4-1-7 PCIe Card Specifications on page 4 - 10 for PCIe specifications. •...
  • Page 106 5 Installation Pull the middle of the Card Clip to unlock it and remove it from the PCIe Drawer. Remove the slot cover from the PCIe Drawer. The thin sheet metal frame should stay in the PCIe Drawer. The slot cover is now removed. 5 - 10 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 107 5 Installation Place the PCIe Card in the PCIe Drawer. Ensure to insert the PCIe Card in the correct opening. Ensure the thin sheet metal frame is positioned between the PCIe Card and the PCIe Drawer to ensure a good conductive contact. Place the Card Clip in the PCIe Card and PCIe Drawer and then rotate the Clip to lock it...
  • Page 108 5 Installation Slide the Card Support so that it supports the side of the PCIe Card. The card should be in small groove so there is support below and above the card. Rotate the Card Support to lock it in place. Insert the PCIe Drawer in the Box PC and then insert the two crosshead screws that hold the PCIe Drawer in place.
  • Page 109 5 Installation Remove the PCIe cover if the PCIe Card has external connectors. (1) Push the lock lever (2) Tilt the PCIe cover (3) Remove the PCIe cover The PCIe Card is installed. 5 - 13 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 110: Mount

    5 Installation Mount This section describes how to mount the Box PC in either a book or wall orientation inside a control panel. WARNING Ensure that installation and post-installation checks of the product are performed by personnel in charge who possess a thorough understand- ing of the machinery to be installed.
  • Page 111: Product Orientation

    5 Installation 5-3-2 Product Orientation The Box PC can be mounted in a book or wall orientation. • For book mount there is one allowed orientation • For wall mount there are two allowed orientations, horizontally mounted and vertically mounted Do not install the Box PC in other orientations.
  • Page 112 5 Installation Provide enough space for good air flow and ensure the following minimum distances are observed around the sides of the Box PC. • Book Mount • Wall Mount in landscape or portrait orientation Item Minimum distance 50 mm 100 mm 50 mm Measure the minimum distances X and Y at the air openings in the sides of the Box PC.
  • Page 113 Box PC. • Do not install the Box PC directly above any heat-generating equipment, such as heaters or transformers. • Do not install the Box PC in a location exposed to direct sunlight. OMRON product OMRON product Natural Cooling ...
  • Page 114: Humidity

    5 Installation OMRON product OMRON product Forced Air Circulation  Room Cooling Cool the entire room where the control panel is located. Cooler Control panel Room Cooling Low Temperatures The Box PC may not start normally if the temperature is below 0°C when the power is turned ON.
  • Page 115: Vibration And Shock

    5 Installation 5-3-5 Vibration and Shock The Box PC is tested for conformity with the sine wave vibration test method (IEC 60068-2-6) and the shock test method (IEC 60068-2-27) of the Environmental Testing for Electrotechnical Products. It is designed so that malfunctioning will not occur within the specifications for vibration and shock. If, how- ever, the Box PC is to be used in a location in which it will be directly subjected to regular vibration or shock, then implement the following countermeasures: •...
  • Page 116: Electrical Environment

    Installation Location Install the Box PC as far away as possible from high-voltage (600 V or higher) and power devices to ensure safe operation and maintenance. Example of Recommended Equipment Arrangement OMRON product Control panel Control panel High-voltage...
  • Page 117 • Keep the wiring between the transformer and the Box PC as short as possible, twist the wires well, and keep the wiring separate from high-voltage and power lines. Power circuits Power supply for general operations circuits I/O power supply for Omron product I/O power supply for Omron product Noise Unit power supply for Omron product...
  • Page 118 5 Installation Wire External I/O Signal Lines Observe the following points when wiring the external I/O signal lines. • To absorb reverse electromotive force when an inductive load is connected to an output signal, con- nect a surge suppressor near the inductive load in an AC circuit, or connect a diode near the induc- tive load in a DC circuit.
  • Page 119 5 Installation External Wiring Wiring, and noise countermeasures in particular, are based on experience, and it is necessary to closely manage wiring based on experience and information in the manuals.  Wiring Routes Each of the following combinations includes different signal types, properties, or levels. They will cause the signal-to-noise ratio to drop due to factors such as electrical induction.
  • Page 120 Metal tubing Power lines Power lines 200 mm OMRON OMRON product product Ground of 200 mm 100 Ω or less Example: Separating an OMRON product from Power Lines 5 - 24 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 121 5 Installation  Wiring Ducts Whenever possible, route the cables and wires through wiring ducts. Install the wiring ducts so that it is easy to route the wires from the Box PC Without Operating Sys- tem directly into the duct. Additional Information Refer to Distance for Cooling on page 5 - 15 for the minimum required distances.
  • Page 122: Book Mount Procedure

    5 Installation 5-3-8 Book Mount Procedure Use the following procedure to mount the Box PC Without Operating System in the book orientation. Additional Information • Refer to 5-4-2 Ground on page 5 - 29 for grounding details. • Refer to 2-9-1 Mounting Brackets on page 2 - 19 for the bracket model. To mount the Box PC: Mount the Bracket to the Industrial Box PC...
  • Page 123: Wall Mount Procedure

    5 Installation • Insert screws through the bracket into the mounting surface. Note that these screws are not in the scope of delivery. • Tighten all four screws with a torque of 0.5 N·m. The Box PC is mounted. 5-3-9 Wall Mount Procedure Use the following procedure to mount the Box PC in the wall orientation.
  • Page 124: Wire

    5 Installation Wire This section describes how to wire the Box PC Without Operating System. 5-4-1 Wiring Warnings and Cautions This section describes the Warnings and Cautions when wiring the Box PC Without Operating System. WARNING Provide safety measures in external circuits to ensure safety in the sys- tem if an abnormality occurs due to malfunction of the product or due to other external factors affecting operation.
  • Page 125: Ground

    5 Installation 5-4-2 Ground This section describes how to ground the Box PC Without Operating System. WARNING Always connect to a ground of 100 Ω or less when installing the prod- uct. Caution The product has an internal non-isolated DC power supply. Circuit ground (0 VDC) and frame ground are connected together.
  • Page 126 5 Installation Considerations for Earthing Methods Local potential fluctuations due to lightning or noise occurred by power devices will cause potential fluctuations between ground terminals of devices. This potential fluctuation may result in device mal- function or damage. To prevent this, it is necessary to suppress the occurrence of a difference in elec- trical potential between ground terminals of devices.
  • Page 127 5 Installation Equipotential Bonding System Equipotential bonding is an earthing method in which steel frames and building structures, metal ducts and pipes, and metal structures in floors are connected together and make connections to the earth trunk line to achieve a uniform potential everywhere across the entire building. We recommend this earthing method.
  • Page 128 5 Installation Star Earthing If the earthing method used for the building is not equipotential bonding or the earthing system is un- known, choose (a) from among the earthing methods given below. (a) Connecting devices and noise sources to separate earth electrodes This is an earthing method to separately ground an earth electrode of the device that is connected with a communications cable or other devices and an earth electrode of a high-power device that could be a noise source, such as a motor or inverter.
  • Page 129 5 Installation Daisy Chain This is an earthing method to connect the device that is connected with a communications cable, other devices, and a device that could be a noise source using a daisy-chain topology to a common earth electrode. This earthing method is not recommended because the device that could be a noise source may inter- fere electromagnetically with other devices.
  • Page 130 5 Installation Ground Connection Details This section provides details about the ground connection. Use the functional ground terminal on the mounting bracket(s) to ground your Industrial Box PC. The washers and nut are supplied with the bracket(s). Refer to Items Supplied with the Brackets on page 5 - 4 for details. Book Mount Mount the ground connection wire to the functional ground terminal...
  • Page 131 5 Installation  Crimp terminals Use crimp terminals with dimensions X = M4 and Y = 8 mm max. 5 - 35 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 132: Wire The Power Connector

    5 Installation 5-4-3 Wire the Power Connector This section describes how to wire the power connector. Precautions for Safe Use • Do not perform a dielectric strength test. • Always use the recommended uninterruptible power supply (UPS) to prevent data loss and other system file integrity issues caused by unexpected power interruption.
  • Page 133 Maximum AWG according to UL/cUL • Power Supply Connector DC Power Supply The OMRON S8VK-series power supply is recommended for use with the Box PC Without Operating System. Additional Information • Refer to 2-9-9 Power Supply on page 2 - 23 for more information.
  • Page 134 5 Installation Power Connector Wiring Procedure Use the following procedure to wire the power connector. 7 mm Remove the sheath from the power supply wires. Precautions for Safe Use Observe the following precautions to prevent broken wires. • When you remove the sheath, be careful not to damage the conductor. •...
  • Page 135: Wire The I/O Connector

    5 Installation 5-4-4 Wire the I/O Connector This section describes how to wire the I/O connector. I/O Connector Wiring Materials Use the supplied I/O connector to connect the inputs and outputs to the Box PC Without Operating System. Recommended I/O conductor sizes for the connector are provided in the table. Wire type Conductor cross-section Solid conductor...
  • Page 136 5 Installation Description Internal Circuit Details Power ON Input The Power ON Input and the UPS Mode Input are bi-di- rectional and isolated. Each input can be wired as sinking (NPN) or sourcing (PNP). Wire these according to the UPS Mode Input output device connected to the inputs.
  • Page 137 5 Installation I/O Connector Wiring Procedure Use the following procedure to wire the I/O connector. 7 mm Remove the sheath from the wires. Precautions for Safe Use Observe the following precautions to prevent broken wires. • When you remove the sheath, be careful not to damage the conductor. •...
  • Page 138: Connect

    5 Installation Connect This section describes how to connect the Box PC Without Operating System. 5 - 42 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 139: Connector Identification

    5 Installation 5-5-1 Connector Identification The Industrial Box PC connectors are shown below. Item Name Description Power connector Lockable power connector I/O connector 2 inputs (UPS signal and power OFF control) and 1 output (Industri- al Box PC power state) USB 3.0 connector 2 USB 3.0 connectors USB 2.0 connector...
  • Page 140: Connection Procedure

    5 Installation 5-5-2 Connection Procedure Use the following procedure to connect the Box PC Without Operating System. Ensure the Box PC is securely fastened to the mounting surface. Ensure the mounted Box PC can be connected to power and peripheral devices. Remove dust covers where applicable and store them in a safe place.
  • Page 141 5 Installation Connect the I/O connector. Hold the black part when inserting the connector, this enables the auto-locking mechanism. Do not tilt the orange levers because this will unlock the connector. Connect an external monitor such as the Industrial Monitor. Connect the monitor to the DVI interface and tighten the fastening screws or use the optional NYML connector.
  • Page 142: Initial Power On

    Connect a keyboard and/or a mouse. Additional Information • If using an OMRON Industrial Monitor this may not be required because it has touch function- ality. • Do not connect additional storage devices before the installation of the operating system completed.
  • Page 143 The Box PC is ON and if an operating system is installed it will start. Precautions for Safe Use Always use the SMART monitoring feature for storage devices that do not comply to the Omron Storage Device Specifications. Monitor the operating temperature and vibrations to ensure they stay within the environmental specifications of the storage device.
  • Page 144: Install Software

    • For an Industrial PC without Operating System download the drivers from the OMRON download website. • For an Industrial PC with a Windows operating system the drivers for most OMRON devices and common third party devices are already available on the product. They will be installed automatically after the initial Windows configuration or upon connection of a device to the Box PC.
  • Page 145: Connect Ups

    • Always use an uninterruptable power supply (UPS) to prevent data loss and other system file integrity issues caused by unexpected power interruption. • Use an Omron S8BA UPS with the correct revision number to prevent improper system shut- down.
  • Page 146: Connect Ups Using The Usb Connector

    • Always use an uninterruptible power supply (UPS) to prevent data loss and other system file integrity issues caused by unexpected power interruption. • Use an Omron S8BA UPS with the correct revision number to prevent improper system shut- down.
  • Page 147 5 Installation Press and hold the UPS power button until On appears on the UPS display. Power ON the Box PC and then wait until the device drivers are successfully installed. Configure the UPS using the UPS Settings Utility. Install the Simple Shutdown Utility. Configure the Simple Shutdown Utility.
  • Page 148: Connect Ups Using The I/O Connector

    • Always use the recommended uninterruptible power supply (UPS) to prevent data loss and other system file integrity issues caused by unexpected power interruption. • Use an Omron S8BA UPS with the correct revision number to prevent improper system shut- down.
  • Page 149 5 Installation Power Supply (S8VK) UPS (S8BA) Output 24 VDC IPC Product 24 VDC 0 VDC Input UPS Mode Input AC (L) 24 VDC AC (N) 0 VDC UPS Mode Input Power Status Output Power Status Output Contact Refer to the UPS S8BA User's Manual (Cat. No. U702) for details. Refer to 5-4-3 Wire the Power Connector on page 5 - 36 for Power Connector details.
  • Page 150 5 Installation Additional Information The default Input sensitivity setting is Standard voltage sensitivity and this is correct. Do not set this parameter to Low voltage sensitivity. Doing so can cause a system malfunc- tion when switching to battery mode. 5 - 54 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 151 Operating Procedures This section provides the operating procedures for the Box PC Without Operating Sys- tem. Power ON ...................... 6 - 2 6-1-1 Power ON Using the Power Button .............. 6 - 2 6-1-2 Power ON Using the Power ON/OFF Input ..........6 - 2 6-1-3 Auto Power ON.....................
  • Page 152: Power On

    6 Operating Procedures Power ON This section provides Power ON details. 6-1-1 Power ON Using the Power Button Start condition: Power is supplied to the Box PC and the Box PC is OFF. Press the power button and release within 1 second. Refer to 2-3 Power Button on page 2 - 8 for the power button location.
  • Page 153: Power Off

    6 Operating Procedures Power OFF This section provides Power OFF details. Before following power OFF procedures below, check that the Box PC Without Operating System is ON by examining the LED indicators on the Box PC. 6-2-1 Power OFF Using the Operating System Shut Down Ensure all programs are closed.
  • Page 154: Power Off Using The Power On/Off Input

    6 Operating Procedures 6-2-3 Power OFF Using the Power ON/OFF Input Ensure all programs are closed. If required, close all active programs. Supply a 24 VDC signal to the Power ON/OFF Input (pins 3 and 4) of the I/O connector. The input signal must remain ON for a minimum of 60 ms and a maximum of 750 ms to be correctly detected by the Box PC Without Operating System.
  • Page 155: Maintenance

    Maintenance This section provides an overview of all maintenance tasks for the Box PC Without Operating System. Preventive Maintenance ................7 - 2 7-1-1 Preventive Maintenance Schedule ............... 7 - 2 7-1-2 Clean the Box PC ..................7 - 4 7-1-3 Keep Software Updated................
  • Page 156: Preventive Maintenance

    Refer to 2-2 LED Indicators on page 2 - 6 for LED details. Monitor storage devices that do not Refer to Storage Device Considerations on page 2 - 20 for details. comply to the Omron specifications Weekly Reference Clean the Box PC Refer to 7-1-2 Clean the Box PC on page 7 - 4 for cleaning details.
  • Page 157 7 Maintenance When the Box PC is not powered Reference for 6 months Confirm both fans rotate immedi- Refer to 7-2-3 Replace the Fan Unit on page 7 - 7 to replace the Fan ately after Power ON. Unit. Replace the Fan Unit when the fans do not rotate smoothly.
  • Page 158: Clean The Box Pc

    This is specifically important for: • Internet browser • Operating system security patches • OMRON software Precautions for Correct Use After an OS update or a peripheral device driver update for the product is executed, the product behavior might be different. Confirm that operation is correct before you start actual operation.
  • Page 159: Corrective Maintenance

    WARNING Do not attempt to disassemble, repair, or modify the product in any way. Doing so may result in malfunction or fire. Contact your local OMRON representative if the corrective maintenance actions did not solve the problem. 7-2-1 Warning and Error Messages Warning and Error messages are provided by the Box PC Without Operating System when there is a potential problem that may cause downtime.
  • Page 160: Remove The Cover

    7 Maintenance 7-2-2 Remove the Cover The Cover of the Box PC Without Operating System provides access to the following items. • Battery • Fan Unit (applies to products with active cooling) The inside of the Cover contains the following information. •...
  • Page 161: Replace The Fan Unit

    7 Maintenance 7-2-3 Replace the Fan Unit The fans are mounted in the Fan Unit. Use the following procedure to replace the Fan Unit. Precautions for Safe Use If the replacement Fan Unit has been stored over 6 months then check the performance of the Fan Unit after replacement.
  • Page 162 7 Maintenance Replace the complete Fan Unit. (1) Push the lever to unlock the Fan Unit. (2) Lift the lever to tilt the Fan Unit. (3) Remove the complete Fan Unit. Insert the new Fan Unit in the Box PC. Ensure the end of the Fan Unit is positioned under the fan guide Connect the Fan Connectors to the board.
  • Page 163: Replace The Battery

    7 Maintenance 7-2-4 Replace the Battery Precautions for Safe Use • The Battery may leak, rupture, heat, or ignite. Never short-circuit, charge, disassemble, heat, or incinerate the Battery or subject it to strong shock. • Dispose of any Battery that has been dropped on the floor or otherwise subjected to exces- sive shock.
  • Page 164 7 Maintenance Lift the battery from the compartment. Disconnect the battery from the battery connector Connect the new battery to the battery connector. Place the new battery in the Box PC. Ensure the wires are at the side of the battery and not on top of the battery. If the wires are on top of the battery this might make closing and opening the cover more difficult.
  • Page 165: Replace A Drive

    7 Maintenance 7-2-5 Replace a Drive Use the following procedure to replace a drive. Prepare the new drive. Additional Information • Refer to 1-4 Product Configuration on page 1 - 5 for the installed drive model. • Refer to 2-9-4 Storage Devices on page 2 - 20 for the available drive models. •...
  • Page 166 7 Maintenance Pull the metal shielding cover out of the Box PC. Insert the drive cover in the drive bracket bay and move it down so that it locks in the drive bracket. 7 - 12 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 167 7 Maintenance Remove the drive bracket from the Box PC using the drive cover. Remove the 4 mounting screws and then remove the drive from the drive bracket. 7 - 13 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 168 7 Maintenance Align the connectors of the replacement drive as shown on the bracket. Then insert the re- placement drive in the bracket and insert the 4 mounting screws . Tighten these screws with a torque of 0.35 N·m. Insert the bracket with the replacement drive into the correct bay of the Box PC. Ensure the bracket is completely in the Box PC with an extra push.
  • Page 169 7 Maintenance Insert the metal shielding cover. Mount the drive cover. The lock lever will click when closed correctly. Restore the drive data. • For products NYB£ and NYP£: • For an Industrial PC with RTOS Controller restore the drive data from a backup. •...
  • Page 170: Replace The Pcie Card

    7 Maintenance 7-2-6 Replace the PCIe Card Use the following procedure to replace the PCIe Card. Prepare: • The PCIe Card Additional Information Refer to 4-1-7 PCIe Card Specifications on page 4 - 10 for PCIe specifications. • The PCIe Card mounting materials: Card Clip and Card Support These are supplied with the Box PC Without Operating System.
  • Page 171 7 Maintenance Push the notch at the bottom of the Card Support up and rotate the Card Support. Slide the Card Support away from the card to create space and to remove it. Pull the middle of the Card Clip to unlock it and remove it from the PCIe Drawer. 7 - 17 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 172 7 Maintenance Remove the PCIe Card from the PCIe Drawer. The PCIe Card is now removed. Place the replacement PCIe Card in the PCIe Drawer. Ensure the PCIe Card is inserted into the correct opening. 7 - 18 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 173 7 Maintenance Place the Card Clip in the PCIe Card and PCIe Drawer and then rotate the Clip to lock it in place. Slide the Card Support so that it supports the side of the PCIe Card. Rotate the Card Support to lock it in place.
  • Page 174 7 Maintenance Insert the PCIe Drawer in the Box PC and then insert the two crosshead screws that hold the PCIe Drawer in place. Remount the Box PC. Confirm normal operation. The PCIe Card is replaced. 7 - 20 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 175 Appendices BIOS ......................A - 2 A-1-1 BIOS Overview ..................... A - 2 A-1-2 BIOS - Main ....................A - 4 A-1-3 BIOS - Advanced ..................A - 4 A-1-4 BIOS - Chipset....................A - 8 A-1-5 BIOS - Boot....................A - 9 A-1-6 BIOS - Security ...................
  • Page 176: A-1 Bios

    Appendices A-1 BIOS This section provides the BIOS information of the Box PC Without Operating System. WARNING Changing BIOS information is only allowed for the engineer in charge that possesses a thorough understanding of the BIOS settings because it can change the behavior of the product. A-1-1 BIOS Overview The BIOS contains settings that influence the behavior of the Box PC Without Operating System.
  • Page 177 Appendices Refer to A-1-5 BIOS - Boot on page A - 9 for Boot details. • Security Refer to A-1-6 BIOS - Security on page A - 10 for Security details. • Save & Exit Refer to A-1-7 BIOS - Save & Exit on page A - 10 for Save and Exit details. BIOS - Navigation and Function Keys The right part of the BIOS screens is divided in two parts.
  • Page 178: A-1-2 Bios - Main

    Appendices A-1-2 BIOS - Main The main setup screen gives platform information about the BIOS, Board Information, Firmware Revi- sion, MAC Addresses and information about the number of Boots and the Running Time. Changeable BIOS Main parameters and their factory default values: •...
  • Page 179 Appendices Item Default / Remark PCI & PCI Express PCI Express Gen 2 Set- Completion Timeout Default tings ARI Forwarding Disabled AtomicOp Requester En- Disabled able AtomicOp Egress Block- Disabled IDO Request Enable Disabled IDO Completion Enable Disabled LTR Mechanism Enable Disabled End-End TLP Prefix Disabled...
  • Page 180 Appendices Item Default / Remark PCI & PCI Express GbE Channel 0 PCI Express Port 0 Enabled ASPM Disabled GbE Channel 1 PCI Express Port 1 Enabled ASPM Disabled PCI Express Port 0, 1 (x4 PEG1 Speed Auto PEG1 ASPM Disabled Gen3) PEG1 De-emphasis Con-...
  • Page 181 Appendices Item Default / Remark CPU Information Display of CPU parame- ters Set Boot Freq Ratio Enabled *2 *1 Hyper-Threading Active Processor Cores Limit CPUID Maximum Disabled Execute Disable Bit Enabled Intel Vitalization Technology Enabled Hardware Prefetcher Enabled Adjacent Cache Line Prefetch Enabled Enabled *2 *1...
  • Page 182: A-1-4 Bios - Chipset

    Appendices Item Default / Remark SMART Settings Disabled Smart Self Test UEFI Network Stack UEFI Network Stack Disabled NVMe Configuration No NVME device found Intel® Ethernet NIC Configuration Link Speed Auto Negotiated Connection I218-LM - Wake On LAN Enabled Unique MAC Address Blink LEDs ®...
  • Page 183: A-1-5 Bios - Boot

    Appendices A-1-5 BIOS - Boot Provides Boot information and configuration settings. Changeable BIOS Boot parameters and their factory default values: Item Default / Remark Quiet Boot Disabled Setup Prompt Timeout Bootup NumLock State Battery Support Auto (Battery Manager) Remain Off Power Loss Control CSM &...
  • Page 184: A-1-6 Bios - Security

    Appendices A-1-6 BIOS - Security Provides security information like BIOS Password and HDD information. WARNING Security setting adjustments should only be performed by the engineer in charge that possesses a thorough understanding of the security set- tings. Selecting non-recommended security settings can put your sys- tem at risk.
  • Page 185: A-2 Dvi Connector Pin Details

    Appendices A-2 DVI Connector Pin Details This section provides the pin details for the DVI-I and the DVI-D connectors. A-2-1 DVI-I Connector Pin Details Pin details of the DVI-I connector. C1 C2 C3 C4 The pin layout represents the DVI-I connector on the Box PC Without Operating System. Pin numbers increase from left to right for every row.
  • Page 186: A-2-2 Dvi-D Connector Pin Details

    Appendices Signal Name Function TMDS clock+ Digital clock+ TMDS clock− Digital clock− Analog red ® ™ For Intel Core i7-4700EQ CPU type Analog green ® ™ For Intel Core i7-4700EQ CPU type Analog blue ® ™ For Intel Core i7-4700EQ CPU type Analog horizontal sync ®...
  • Page 187 Appendices Signal Name Function TMDS data 0− Digital blue− (link 1) and digital sync TMDS data 0+ Digital blue+ (link 1) and digital sync 0 VDC TMDS data 0/5 shield Not connected Not connected 0 VDC TMDS clock shield TMDS clock+ Digital clock+ TMDS clock−...
  • Page 188: A-3 Rs-232C Connector Pin Details

    Appendices A-3 RS-232C Connector Pin Details The pin layout represents the RS-232C connector on the Box PC. Signal Name 0 VDC The 0 VDC pin is internally connected to the ground connection. Additional Information Refer to 5-4-2 Ground on page 5 - 29 for grounding details. A - 14 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 189: Index

    Index I - 1 NY-series Industrial Box PC Without Operating System User's Manual (W586)
  • Page 190 Index Index Link/Act indicator ............4 - 19 Specifications ............4 - 19 Speed indicator ............4 - 19 Accessory kit ..............2 - 18 Battery ..............2 - 17,7 - 6 Fan error .................2 - 7 Replace ...............7 - 9 Fan Unit ................ 2 - 17 Replacement ...............7 - 6 Replace ...............7 - 7 Battery low ..............2 - 7...
  • Page 191 Index Specifications ............4 - 18 USB flash drives ............2 - 20 PCIe Card ..............2 - 11 Install ................5 - 9 Replace ..............7 - 16 Wall mount ..............2 - 19 Specifications ............4 - 10 Wall mounting ............... 5 - 27 Power button ..............
  • Page 194 The Netherlands Hoffman Estates, IL 60169 U.S.A. Tel: (31)2356-81-300/Fax: (31)2356-81-388 Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 © OMRON Corporation 2017 All Rights Reserved. OMRON (CHINA) CO., LTD. OMRON ASIA PACIFIC PTE. LTD. In the interest of product improvement, Room 2211, Bank of China Tower, No.

This manual is also suitable for:

Nyb1c-*100 seriesNyb25-*100 series

Table of Contents