Omron NY532-1500 User Manual page 232

Ny-series ipc machine controller industrial panel pc / industrial box pc
Hide thumbs Also See for NY532-1500:
Table of Contents

Advertisement

9 Motion Control Functions
Example for Negative Direction
The following example illustrates when positioning is performed towards a target position of −20 when
the command current position is 50.
Modulo maximum
position setting
value: 100
0
Modulo minimum
position setting
value: −70
Moves in negative direction.
Example for Current Direction
The following example illustrates when positioning is performed towards a target position of −20 when
the command current position is 50.
Modulo maximum
position setting
value: 100
0
Modulo minimum
position setting
value: −70
The direction of the previous operation is given in the Command Direction in the Axis Variable.
9-38
Command current position:
Target position:
−20
Command current position:
Target position:
−20
If the previous operation was
in the negative direction,
motion is in the negative
direction.
NY-series Industrial Panel PC / Industrial Box PC Motion Control User's Manual (W559)
50
Target position:
−20
50
Target position:
−20
If the previous operation was in
the positive direction, motion is in
the positive direction.