Mitsubishi Electric HG-MR Instruction Manual page 273

General-purpose ac
Table of Contents

Advertisement

8. HG-JR SERIES
Item
Power supply capacity
Rated output
Continuous running
duty (Note 1)
Rated torque
Maximum torque
Rated speed (Note 1)
Maximum speed
Instantaneous permissible speed
Standard
Power rate at
With an
continuous rated
electromagnetic brake
torque
Rated current
Maximum current
Standard [× 10
With an
Moment of inertia J
electromagnetic brake
Recommended load to motor inertia ratio
(Note 2)
Speed/position detector
Oil seal
Thermistor
Insulation class
Structure
Ambient
temperature
Ambient
humidity
Environment (Note 4)
Ambience
Altitude
Vibration resistance
(Note 5)
Vibration rank (Note 6)
L
Permissible load for
Radial
the shaft (Note 7)
Thrust
Standard
With an
Mass
electromagnetic brake
Power
supply
Cooling fan
Rated current
Servo motor
601(B)
Refer to "Power supply equipment capacity and generated loss of servo amplifiers"
[kW]
6.0
[N•m]
57.3
[N•m]
172
[r/min]
[r/min]
[r/min]
[kW/s]
187
167
[kW/s]
[A]
31
[A]
108
-4
kg•m
2
]
176
196
[× 10
-4
kg•m
2
]
Totally-enclosed,
natural-cooling
(IP rating: IP67 (Note 3))
Operation
Storage
Operation
Storage
[mm]
85
[N]
2450
[N]
[kg]
53
65
[kg]
Voltage/
Frequency
Power
consumption
[W]
[A]
HG-JR 1000 r/min series
(Compatible with 3-phase 200 V AC, low inertia/large capacity)
801(B)
12K1(B)
15K1
in Servo Amplifier Instruction Manual.
8.0
12
15
76.4
115
143
229
345
429
2000
2300
265
420
418
243
394
47
60
67
165
208
231
220
315
489
240
336
10 times or less
22-bit encoder common to absolute position/incremental
(resolution per servo motor revolution: 4194304 pulses/rev)
None
155 (F)
0 °C to 40 °C (non-freezing)
-15 °C to 70 °C (non-freezing)
10 %RH to 80 %RH (non-condensing)
10 %RH to 90 %RH (non-condensing)
Indoors (no direct sunlight),
free from corrosive gas, flammable gas, oil mist, dust, and dirt
2000 m or less above sea level (Note 9)
X, Y: 24.5 m/s
2
116
2940
980
62
86
120
74
97
3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
65 (50 Hz)/85 (60 Hz)
0.20 (50 Hz)/0.22 (60 Hz)
8 - 12
20K1
25K1
30K1
20
25
30
191
239
286
573
717
858
1000
1500
1725
582
748
594
94
95
121
318
313
399
627
764
1377
With
Built-in
Totally-enclosed, force-cooled
(IP rating: IP44 (Note 3))
X, Y: 9.8 m/s
V10
140
3234
1470
145
165
215
120 (50 Hz)/
0.39 (50 Hz)/
0.52 (60 Hz)
37K1
37
353
1059
761
152
495
1637
2
140
4900
1960
240
175 (60 Hz)