05.08
4.4

Safe Brake Control (SBC)

Description
Safe Brake Control is used to control actuators that function according to the
closed–circuit principle (e.g. brake).
Warning
!
The Safe Brake Control function does not detect faults in the brake itself – such as
e.g. brake winding short–circuit, worn brakes and similar.
If a cable breaks, this is only recognized by the Safe Brake Control function when
the status changes, i.e. when the brake is applied/released.
Functional features of Safe Brake Control (SBC)
S When Safe Torque Off is selected or when safety monitors are triggered, "SBC"
is performed with safe pulse cancelation.
S Unlike conventional brake control, SBC is implemented via p1215 through two
channels.
S SBC is initiated independently of the brake control mode set in p1215. However,
SBC is not recommended for p1215 = 0 or 3.
S The function must be enabled via parameter.
S Each time Safe Torque Off is selected, the holding brake is applied immediately
with a forced checking procedure carried out.
Enabling the Safe Brake Control (SBC) function
The Safe Brake Control function is enabled via the following parameters:
S p9602
S p9802
The Safe Brake Control function only becomes active if at least one safety monitor-
ing function is enabled (i.e. p9601 = p9801  0).
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
"SI enable safe brake control (Control Unit)"
"SI enable safe brake control (Motor Module)"
Safety Functions Integrated in the Drive
4.4 Safe Brake Control (SBC)