05.08
Response
Remedy
Program
continuation
27224
Parameter
Explanation
Response
Remedy
Program
continuation
27225
Parameter
Explanation
Response
Remedy
Program
continuation
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
10.2 NCK safety alarms for SINUMERIK 840D sl
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Check the module in the S7 PROFIBUS configuration
Switch control system OFF and ON again.
PROFIsafe: F module MD %1[%2] – MD %3[%4]: Double assign-
PROFIsafe address
ment of the
%1 = MD name 1
%2 = MD field index 1
%3 = MD name 2
%4 = MD field index 2
In the NCK MD or in the S7 F parameters, the same PROFIsafe ad-
dress has been parameterized for the F modules parameterized in the
specific machine data. This means that a clear communications relati-
onship between the F master and F slave is not possible.
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Check and correct the S7 F parameterization and NCK–MD.
Switch control system OFF and ON again.
PROFIsafe: Slave %1, configuration error, %2
%1 = PROFIBUS slave address
%2 = configuration error
An error has occurred during the evaluation of the S7 PROFIBUS con-
figuration for the specific slave. This is further specified in alarm param-
eter %2.
%2 = PRM header: The PRM telegram for this slave could not clearly
be interpreted.
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Check the S7 PROFIBUS configuration and correct.
Switch control system OFF and ON again.
Diagnostics