Siemens SINUMERIK 840D sl Function Manual page 348

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data Description
8.2 Parameters for SINAMICS S120
r9739[0...1]
SI motion, diagnostics result list 7
Displays result list 7 where for a crosswise data comparison with the control,
led to an error.
[0]: Result list second channel
[1]: Result list drive
Bit field
Bit 00
Actual value > Upper limit SN25+
Bit 01
Actual value > Lower limit SN25+
Bit 02
Actual value > Upper limit SN25–
Bit 03
Actual value > Lower limit SN25–
Bit 04
Actual value > Upper limit SN26+
Bit 05
Actual value > Lower limit SN26+
Bit 06
Actual value > Upper limit SN26–
Bit 07
Actual value > Lower limit SN26–
Bit 08
Actual value > Upper limit SN27+
Bit 09
Actual value > Lower limit SN27+
Bit 10
Actual value > Upper limit SN27–
Bit 11
Actual value > Lower limit SN27–
Bit 12
Actual value > Upper limit SN28+
Bit 13
Actual value > Lower limit SN28+
Bit 14
Actual value > Upper limit SN28–
Bit 15
Actual value > Lower limit SN28–
Bit 16
Actual value > Upper limit SN29+
Bit 17
Actual value > Lower limit SN29+
Bit 18
Actual value > Upper limit SN29–
Bit 19
Actual value > Lower limit SN29–
Bit 20
Actual value > Upper limit SN30+
Bit 21
Actual value > Lower limit SN30+
Bit22
Actual value > Upper limit SN30–
Bit23
Actual value > Lower limit SN30–
See also: C01711
Unit:
Default value:
r9744
SI message buffer changes, counter
Displays the changes of the safety message buffer. This counter is increm-
ented every time that the safety message buffer changes.
This is used to check whether the safety message buffer has been read out
consistently.
See also r9747, r9748, r9749, p9752, r9754, r9755, r9756, r9759
Unit:
Default value:
r9747[0...63]
SI message code
Displays the number of the safety messages that have occurred.
See also r9744, r9748, r9749, r9754, p9752, r9753, r9754, r9755, r9756, r9759
Unit:
Default value:
8-348
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Minimum value:
Maximum value:
Minimum value:
Maximum value:
Minimum value:
Maximum value:
Checksum:
Protection level:
Yes
3
Data type:
Effective:
POWER ON
Unsigned32
Checksum:
Protection level:
3
Data type:
Effective:
Unsigned16
Checksum:
Protection level:
3
Data type:
Effective:
Unsigned16
© Siemens AG 2008 All Rights Reserved