05.08
C01798
Response
Acknowledgement
Explanation
Remedy
C01799
Response
Acknowledgement
Explanation
Remedy
List of faults and alarms (Motor Module)
F30600
Response
Acknowledgement
Explanation
Remedy
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
SI motion: Test stop running
NONE
IMMEDIATELY (POWER ON)
The test stop is active.
Message value: (r9749, decimal):
None necessary.
The message is withdrawn when the test stop is completed.
SI motion: Acceptance test mode is active
NONE
IMMEDIATELY (POWER ON)
The acceptance test mode is active. The POWER ON messages of the
safe motion monitoring functions can be acknowledged during the ac-
ceptance test using the RESET key of the higher–level control.
None necessary.
The message is withdrawn when exiting the acceptance test mode.
SI MM: STOP A initiated
OFF2
IMMEDIATELY (POWER ON)
The "Safety Integrated" function integrated in the drive on the Motor
Module (MM) has detected a fault and initiated STOP A (pulse can-
cellation via the safety shutdown path of the Motor Module).
– Forced checking procedure of the safety shutdown path of the
Motor Module unsuccessful.
– Subsequent response to fault F30611 (defect in a monitoring channel).
Fault value (r0949, decimal):
0:
Stop request from the Control Unit
Pulses cancelled although SH not selected and there is not
1005:
internal STOP A present.
Pulses enabled although SH is selected or an internal STOP A
1010:
is present.
Subsequent response to fault F30611
9999:
Select safe standstill and then deselect again.
– Replace the Motor Module involved.
Re fault value = 9999:
– Carry out diagnostics for fault F30611.
10.3 Safety messages for SINAMICS S120