Siemens SINUMERIK 840D sl Function Manual page 474

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Diagnostics
10.2 NCK safety alarms for SINUMERIK 840D sl
10-474
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
95
Cam position: The setting in MD 36936
$MA_SAFE_CAM_POS_PLUS[5] + $MA_SAFE_CAM_TOL does not
correspond with the associated drive parameter assignment.
Remedy
Safe cam 6+ (+ tolerance). Enter the same MDs.
96
Cam position: The setting in MD 36936
$MA_SAFE_CAM_POS_PLUS[5] does not correspond with the associ-
ated drive parameter assignment.
Remedy
Safe cam 6+. Enter the same MDs.
97
Cam position: The setting in MD 36937 $MA_SAFE_CAM_POS_
MINUS[5] + $MA_SAFE_CAM_TOL does not correspond with the
associated drive parameter assignment.
Remedy
Safe cam 6– (+ tolerance). Enter the same MDs.
98
Cam position: The setting in MD 36937 $MA_SAFE_CAM_POS_
MINUS[5] does not correspond with the associated drive parameter
assignment.
Remedy
Safe cam 6–. Enter the same MDs.
99
Cam position: The setting in MD 36936
$MA_SAFE_CAM_POS_PLUS[6] + $MA_SAFE_CAM_TOL does not
correspond with the associated drive parameter assignment.
Remedy
Safe cam 7+ (+ tolerance). Enter the same MDs.
100
Cam position: The setting in MD 36936
$MA_SAFE_CAM_POS_PLUS[6] does not correspond with the associ-
ated drive parameter assignment.
Remedy
Safe cam 7+. Enter the same MDs.
101
Cam position: The setting in MD 36937 $MA_SAFE_CAM_POS_
MINUS[6] + $MA_SAFE_CAM_TOL does not correspond with the
associated drive parameter assignment.
Remedy
Safe cam 7– (+ tolerance). Enter the same MDs.
102
Cam position: The setting in MD 36937 $MA_SAFE_CAM_POS_
MINUS[6] does not correspond with the associated drive parameter
assignment.
Remedy
Safe cam 7–. Enter the same MDs.
© Siemens AG 2008 All Rights Reserved