Siemens SINUMERIK 840D sl Function Manual page 537

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

05.08
Remedy
Program
continuation
27900
Parameter
Explanation
Response
Remedy
Program
continuation
27901
Parameter
Explanation
Response
Remedy
Program
continuation
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
10.2 NCK safety alarms for SINUMERIK 840D sl
Please contact the Siemens I DT MC Hotline with the error text
– Tel. 0180 / 5050 – 222 (Germany)
– Fax 0180 / 5050 – 223
– Tel. +49–180 / 5050 – 222 (outside Germany)
– Fax +49–180 / 5050 – 223
mailto:techsupport@ad.siemens.de
Power–down the control and power–up again
Profibus–DP: SI fault, axis %1, code %2, value %3, time %4
%1 axis number
%2 fault code of the drive (p9747)
%3 fault value of the drive (p9749)
%4 fault time of the drive (p9748)
SINAMICS drive fault.
Alarm display
Fault codes/fault values, refer to the drive documentation.
The alarm is no longer displayed when the alarm cause has been re-
moved. No other operator actions are required.
Profibus–DP: SI fault, axis %1, code %2, value %3, time %4
%1 axis number
%2 fault code of the drive (p9747)
%3 fault value of the drive (p9749)
%4 fault time of the drive (p9748)
SINAMICS drive fault.
Alarm display
Fault codes/fault values, refer to the drive documentation.
Remove the error and press RESET.
Diagnostics
10-537

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents