Configuring And Parameterizing The Profisafe I/O - Siemens SINUMERIK 840D sl Function Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Connecting Sensors/Actuators
7.2 Connecting I/O via PROFIsafe
7.2.3

Configuring and parameterizing the PROFIsafe I/O

The information on configuring and parameterizing the PROFIsafe I/O provided in
this chapter essentially refers to the specific requirements of SIMATIC. Complete
information on configuring and parameterizing PROFIsafe components from
Siemens is provided in the SIMATIC Manuals:
References:
Distributed I/O System ET 200S, Manual
Distributed I/O System ET 200S, Fail–Safe Modules, Manual
Distributed I/O System ET 200pro, Fail–Safe Modules
Distributed I/O Station ET 200eco, Fail–Safe I/O Module
ASIsafe DP/AS–i F–Link
Configuring
The F I/O are configured while configuring the standard PROFIBUS configuration
using STEP 7.
After the "S7 Distributed Safety" option package or the S7 F configuration package
has been installed (refer to the Chapter 3.1 "System prerequisites) the F modules
are available in the hardware catalog of STEP 7: HW Config (if the hardware cata-
log is not displayed, open it using the menu command View > Catalog).
Parameter assignment
Both the standard and F parameterization of the F modules is carried out using the
relevant properties dialog box of the module. Select the appropriate DP slave (e.g.
IM 151–1) in the station window and then open the properties dialog box of the
relevant F module in the detailed view.
Note
The parameter assignments specified in this chapter only refer to the ET 200S
modules. Other PROFIsafe devices have a different parameter assignment.
7-202
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
© Siemens AG 2008 All Rights Reserved
05.08