Diagnostics
10.3 Safety messages for SINAMICS S120
Remedy
F30659
Response
Acknowledgement
Explanation
Remedy
10-570
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
129:
Safety parameters for the Motor Module corrupted.
131:
Internal software error on the Control Unit.
255:
Internal Motor Module software error.
Re–commission the safety functions.
– Upgrade the Control Unit software.
– Upgrade the Motor Module software.
– Replace the CompactFlash Card.
SI MM: Write task for parameter rejected
OFF2
IMMEDIATELY (POWER ON)
The write task for one or several Safety Integrated parameters on the
Motor Module (MM) was rejected.
Note:
This fault does not result in a safety stop response.
Fault value (r0949, decimal):
10:
An attempt was made to enable the SH function although this cannot be
supported.
11:
An attempt was made to enable the SBC function although this cannot
be supported.
13:
An attempt was made to enable the SS1 function although this cannot
be supported.
14:
An attempt was made to enable the safe motion monitoring with the
higher–level control although this cannot be supported.
See also: r9771 (SI common functions (Control Unit)), r9871 (SI com-
mon functions (Motor Module))
Re fault value = 10, 11:
– Check whether there are faults in the safety function alignment
between the Control Unit and the Motor Module involved (F01655,
F30655) and if required, carry out diagnostics for the faults involved.
– Use a Motor Module that supports the function safe standstill or safe
brake control.
– Upgrade the Motor Module software.
– Upgrade the Control Unit software.